38
11.2.4 Connect the Cable to the Indoor Unit
1. The inside and outside connection cable can be connected without removing the front grille.
5.
Connection cable
between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 × 1.5
mm
2
flexible cord, type designation 60245 IEC 57 or heavier cord. Do not use joint connection cable. Replace the
wire if the existing wire (from concealed wiring, or otherwise) is too short.
6. Bind all the indoor and outdoor connection cable with tape and route the connection cable via the escapement.
7. Remove the tapes and connect the connection cable between indoor unit and outdoor unit according to the
diagram below.
Terminals on the indoor unit
Colour of wires
Terminals on the outdoor unit
1
2
3
1
2
3
WARNING
This equipment must
be properly earthed.
Recommended
length (mm)
a
b
c
d
35
35 35 55
Recommended
length (mm)
Connection cable
Indoor & outdoor
connection cable
Escapement
Earth Wire
longer than
others AC
wires for
safety reason
Holder
Indoor & outdoor
connection cable
Outdoor unit
Tape
Terminal Board
Note:
Secure the connection cable onto the control board with the holder.
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires for safety reason.
11.2.4.1 Wire
Stripping,
Connecting Requirement
Wire stripping
5 mm
or more
Conductor
over inserted
No loose strand
when inserted
Indoor/outdoor
connection
terminal board
10
±
1
mm
Conductor
fully inserted
Conductor not
fully inserted
(gap between wires)
ACCEPT
PROHIBITED
PROHIBITED