71
Indoor fan control
o
During any operation mode combines with nanoe-G operation, fan speed follows respective operation mode.
However, nanoe-G system enabled when fan speed ≥ 500 rpm to ensure proper negative ion distribution,
nanoe-G system disabled when fan speed < 500 rpm.
o
During nanoe-G individual operation, only Auto Fan Speed is allowed. Even if Fan Speed button is pressed,
no signal is sent to the unit and no change on remote control display.
Airflow direction control
o
During any operation mode combines with nanoe-G operation, airflow direction follows respective operation
mode.
o
During nanoe-G individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, no
signal is sent to the unit and no change on remote control display.
Timer control
o
When ON Timer activates when unit stops, previous operation resumes and restored last saved nanoe-G
operation status.
o
When ON Timer activates during any operation, no change on current operation.
o
When OFF Timer activates during any operation, all operation stops and the latest nanoe-G operation status
is saved.
Indicator
o
When nanoe-G starts, nanoe-G indicator ON.
Remote control receiving sound
o
Normal operation
nanoe-G operation
: Beep
o
Nanoe-G operation
Normal operation
: Beep
o
Stop
nanoe-G individual operation : Beep
o
Nanoe-G individual operation
Stop
: Long Beep
Power failure
o
During nanoe-G individual operation, if power failure occurs, after power resumes, nanoe-G individual
operation resumes immediately.
o
During combination operation, if power failure occurs, after power resumes, combination operation resume
immediately.
nanoe-G check mode
o
To enable nanoe-G check mode, during nanoe-G operation ON:
iCOMFiAUTO-XHEATCOOLDRYFAN
F
SHOWER
DIRECT
AM
PM
AM
ON
OFF
PM
SET
Transmit ECO demo code and
after 30 seconds return to normal
mode.
Press continously for 5s
Transmit check code
and after 30 seconds return to normal
mode.
Transmit sunlight sensor check code
and after 30 seconds return to normal
mode.
Remote control normal mode
o
If there is abnormal discharge, nanoe-G indicator blinks immediately.