![Panasonic CS-PC12TKF Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/panasonic/cs-pc12tkf/cs-pc12tkf_service-manual_1507893007.webp)
7
Model
Indoor CS-PC24TKF
Outdoor CU-PC24TKF
Performance Test Condition
ISO 5151 (T1)
Power Supply
Phase, Hz
Single, 50
V 220
240
Cooling
Capacity
kW 7.03
7.03
Btu/h 24000
24000
kJ/h 25310
25310
Running Current
A
12.4
12.3
Input Power
W
2.57k
2.70k
EER
W/W 2.74
2.60
Btu/hW 9.34
8.89
Power Factor
%
94
91
Indoor Noise (H / L)
dB-A
48 / 42
49 / 42
Power Level dB
61 / -
62 / -
Outdoor Noise (H / L)
dB-A
57 / -
58 / -
Power Level dB
72 / -
73 / -
Max Current (A) / Max Input Power (W)
16.8 / 3.64k
Starting Current (A)
59.0
Compressor
Type
Hermetic Motor / Rotary
Motor Type
Induction (2 poles)
Output Power
W
2.0k
Indoor Fan
Type
Cross-Flow
Fan
Material
ASG33
Motor Type
DC Motor (8 poles)
Input Power
W
94.8
94.8
Output Power
W
40
Speed
QLo rpm
910
Lo rpm
1000
Me rpm
1100
Hi rpm
1220
SHi rpm
1300
Outdoo
r Fa
n
Type
Propeller
Fan
Material
PP
Resin
Motor Type
AC / Induction (6 poles)
Input Power
W
157.3
173.8
Output Power
W
88
Speed
Lo rpm
440
500
Hi rpm
860
890
Moisture Removal
L/h (Pt/h)
4.0 (8.5)
Indoor Airflow
QLo m
3
/min (ft
3
/min) 15.7
(556)
Lo m
3
/min (ft
3
/min) 17.3
(611)
Me m
3
/min (ft
3
/min) 19.0
(672)
Hi m
3
/min (ft
3
/min) 21.1
(745)
SHi m
3
/min (ft
3
/min) 22.5
(794)
Outdoor
Airflow
Lo m
3
/min (ft
3
/min)
26.6 (941)
30.3 (1073)
Hi m
3
/min (ft
3
/min)
52.0 (1840)
54.0 (1910)
Refrigeration
Cycle
Control Device
Capillary Tube
Refrigerant Oil
cm
3
ATMOS NM56M or Suniso 4GDID (700)
Refrigerant Type
g (oz)
R22, 1.28k (45.2)