32
11.2.3 Indoor Unit Installation
Do not turn over the unit without it’s shock absorber during pull out the piping.
It may cause intake grille damage.
Use shock absorber during pull out the piping to protect the intake grille from damage.
•
•
Intake grille
Piping
pull ou
t the
pip
ing
Piping
Shock absorber
pull o
ut th
e p
ipin
g
11.2.3.1 For the Right Rear Piping
Install the Indoor Unit
Pull out the Indoor piping
Step-2
Secure the Indoor Unit
Step-1
Step-3
• Insert the cables from bottom of the unit through the control board hole until
terminal board area.
Insert the power supply cord and connection cable
Step-4
11.2.3.2 For the Right and Right Bottom
Piping
Install the Indoor Unit
Pull out the Indoor piping
Step-2
Insert the power supply cord and connection cable
Secure the Indoor Unit
Step-1
Step-3
Step-4
• Insert the cables from bottom of the unit through the control board hole until
terminal board area.
11.2.3.3 For the Embedded Piping
• Use a spring bender or equivalent to bend the piping so that the piping is not
crushed.
• When determining the dimensions of the piping, slide the unit all the way to the
left on the installation plate.
• Refer to the section “Cutting and flaring the piping”.
Bend the embedded piping
Cut and flare the embedded piping
Replace the drain hose
Pull the connection cable into Indoor Unit
• The power supply cord and indoor unit and outdoor unit connection cable can
be connected without removing the front grille.
• Please refer to “Connecting the piping” column in outdoor unit section.
(Below steps are done after connecting the outdoor piping and gas-leakage
confirmation.)
Connect the piping
• Please refer to “Insulation of piping connection” column as mentioned in
indoor/outdoor unit installation.
Install the Indoor Unit
Secure the Indoor Unit
Insulate and finish the piping
Step-1
Step-2
Step-3
Step-4
Step-5
Step-6
Step-7
Step-8
In case of the cover is cut,
keep the cover at the rear
of chassis as shown in
the illustration for future
reinstallation.
(Left, right and 2 bottom
covers for piping.)
How to keep the cover
Hook the indoor unit onto the
upper portion of installation
plate. (Engage the indoor
unit with the upper edge of
the installation plate). Ensure
the hooks are properly
seated on the installation
plate by moving it in left
and right.
Press the lower left and right
side of the unit against the
installation plate until hooks
engages with their slot (sound
click).
Right Rear piping
Right and Right Bottom piping
Install the indoor unit
Secure the Indoor Unit
Insert the connection cable
Cover for the
bottom piping
Cover for the
bottom piping
Tape it with piping
in a position as
mentioned in Fig.
below.
Cover for
the right
piping
Piping
Drain
hose
Cover
for the
left
piping
Cover for piping
Cover for the
bottom piping
Tape it with piping in a
position as mentioned
in Fig. below.
Cover for
the right
piping
Piping
Drain hose
Cover for
the left
piping
Drain hose
Sleeve for
piping hole
Indoor unit
Hooks at
installation
plate
Piping
Installation
plate
Unit’s
hook
Guide
surface
Connection cable
About
70 – 80 mm
Connection cable
Gas side
piping
Liquid side
piping
Drain hose
To take out the unit, push the
marking at
the bottom unit, and pull it slightly towards you to
disengage the hooks from the unit.
marking
(This can be used for left rear piping and bottom
piping also.)