![Panasonic CS-PC12TKF Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/panasonic/cs-pc12tkf/cs-pc12tkf_service-manual_1507893030.webp)
30
11.2 Indoor Unit
11.2.1 How to Fix Installation Plate
The mounting wall shall be strong and solid enough to prevent it from the vibration.
3
4
B
A
C
C
128 mm
PIPE
HOLE
CENTER
128mm TO
PIPE HOLE
CENTER
A
Ceiling
Wall
Wall
Installation
plate
1
2
screw
More than
1
More than
1
Measuring Tape
Indoor unit
184 mm
128 mm
222 mm
128 mm
More
than
2
PIPE
HOLE
CENTER
PIPE
HOLE
CENTER
128mm TO
PIPE HOLE
CENTER
128mm TO
PIPE HOLE
CENTER
For best strength of
INDOOR unit installation,
it is highly recommended
to locate “ ” at 5 position
as shown.
Model
Dimension
1
2
3
4
5
6
PC12***
470 mm
90 mm
380 mm
420 mm
15 mm
35 mm
3
4
5
6
Ceiling
Wall
Wall
Installation plate
1
2
screw
More than
1
More than
1
Measuring Tape
Indoor unit
More
than
2
For best strength of
INDOOR unit installation,
it is highly recommended
to locate “ ” at 5 position
as shown.
256 mm
128 mm
128 mm
256 mm
128 mm
Model
Dimension
1
2
3
4
5
6
PC18***, PC24***
605 mm
95 mm
550 mm
550 mm
210 mm
260 mm
The center of installation plate should be at more than
1
at right and left of the wall.
The distance from installation plate edge to ceiling should more than
2
.
From installation plate center to unit’s left side is
3
.
From installation plate center to unit’s right side is
4
.
B
: For left side piping, piping connection for liquid should be about
5
from this line.
: For left side piping, piping connection for gas should be about
6
from this line.