53
12.9 Quiet Operation
(For Cooling Operation or cooling region of Soft Dry Operation)
To provide quiet cooling operation condition.
Once the Quiet Operation is set at the remote control, the Quiet LED brightness will be dimmed. The sound level
will reduce around 2dB(A) for Lo fan speed or 3dB(A) for Hi/Me fan speed against the present operation sound
level.
Dew formation become severe at Quite Lo Cool, therefore Quiet Lo cool operated only 1 hour 30 minutes
(1 hour QLo, 30 minutes QLo + 50 rpm).
Manual Airflow Direction:
o
RPM control during Lo cool
Quiet
LED
Fan
OFF
OFF
CLo
ON
QLo
1 hr
30 min
1 hr
30 min
QLo
QLo+50
QLo+50
QLo+100
QLo+100
o
RPM control during Hi & Me cool
Quiet LED
Fan
OFF
OFF
Hi/Me
Q Hi/Q Me
Q Hi/Q Me
Hi/Me
Press Quiet
Press Quiet
Cancel Quiet
ON
ON
Time (Hour)
Auto Fan Speed
Indoor
fan
Compressor
ON
ON
OFF
Quiet Hi (if before thermo off)
Quiet ME (after thermo off)
Stop
Lo-
Variable
RPM
160”
Lo-
Lo-
Lo-
40”
Stop
40”
30”
20”
30”
Quiet operation stops when:
o
Quiet button is pressed again.
o
JETSTREAM button is pressed.
o
Stop by OFF/ON button.
o
OFF Timer activates.
o
Sleep mode timer delay OFF.
o
Operation mode button is changed.