20
8. Wiring Connection Diagram
8.1 CS-PC12TKF
CU-PC12TKF
TRADEMARK
YELLOW
(YEL) OR (C)
BLUE
(BLU)
OR (R)
RED
(RED)
OR (S)
COMPRESSOR TERMINAL
THE PARENTHESIZED
LETTER IS INDICATED
ON TERMINAL COVER
EVAPORATOR
GROUNDING
TERMINAL
COMPLETE
Y/G
TERMINAL
BOARD
RY-PWR
BL
L
N
1
2
W
AC303
(WHT)
AUTO SW
(SW01)
CN-STM1
(WHT)
CN-STM3
(BLU)
CN-TH
(RED)
CN-DISP
(YL
W)
CN-FB
(WHT)
FUSE301
1
5
1
5
BR
M
M
BR
R
O
Y
P
R
O
Y
P
W
W
W
W
W
W
W
B
R
Y
W
O
BR
1
1
t°
t°
1
5
1
5
4
7
7
1
1
1
3
3
5
NOISE FILTER
CIRCUIT
SUCTION TEMP. SENSOR (THERMISTOR)
PIPING TEMP. SENSOR (THERMISTOR)
CN–DISP (WHT)
REMOTE CONTROLLER
FAN MOTOR
UP DOWN
LOUVER MOTOR
(OUTER)
UP DOWN
LOUVER MOTOR
(INNER)
RECTIFICATION
CIRCUIT
CN-PCFM
(WHT)
FAN MOTOR
CIRCUIT
ELECTRONIC
CONTROLLER
(DISPLAY & RECEIVER)
T3. 15A L250V
BR
ELECTRONIC CONTROLLER
(MAIN)
SINGLE
PHASE
POWER
SUPPLY
TEMP.
FUSE
102°C
(250V 4.5A)
PL
1
M
~
M
1~
M
1~
YELLOW
YELLO
W OR GRA
Y
BLUE
BLUE
RED
BLUE
RED
BLUE
FAN MOTOR
CAPACITOR
COMPRESSOR
CAPACITOR
TERMINAL
BOARD
1
2
REMARKS
BL :
BLACK
B/BLU :
BLUE
BR :
BROWN
G/GRN : GREEN
O :
ORANGE
P :
PINK
R :
RED
W/WHT : WHITE
Y/G
: YELLOW / GREEN
Y/YLW : YELLOW
Resistance of Indoor Fan Motor Windings
MODEL CS-PC12TKF
CONNECTION ACXA92-00090
BLUE-YELLOW 336
Ω
YELLOW-RED 306
Ω
Note: Resistance at 25°C of ambient temperature.
Resistance of Outdoor Fan Motor Windings
MODEL CU-PC12TKF
CONNECTION ACXA95-00440
BLUE-YELLOW 227
Ω
YELLOW-RED 163
Ω
Note: Resistance at 20°C of ambient temperature.
Resistance of Compressor Windings
MODEL CU-PC12TKF
CONNECTION 2KS210D5AA06
C-R 2.279
Ω
C-S 3.526
Ω
Note: Resistance at 20°C of ambient temperature.