![Panasonic CS-ME12NKE Скачать руководство пользователя страница 300](http://html.mh-extra.com/html/panasonic/cs-me12nke/cs-me12nke_technical-and-service-manual_1507790300.webp)
4
English
1. General
This booklet briefly outlines where and how to install
the air conditioning system. Please read over the
entire set of instructions for the indoor and outdoor
units and make sure all accessory parts listed are with
the system before beginning.
1-1. Tools Required for Installation (not supplied)
1. Standard screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Tape measure
5. Carpenter’s level
6. Sabre saw or key hole saw
7. Hacksaw
8. Core bits
9. Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for deburring)
1-2. Accessories Supplied with Unit
Table 1
1-3. Optional Copper Tubing Kit
Copper tubing for connecting the outdoor unit to the
indoor unit is available in kits which contain the narrow
and wide tubing, fittings and insulation. Consult your
nearest sales outlet or air conditioning workshop.
1-4. Type of Copper Tube and Insulation Material
If you wish to purchase these materials separately
from a local source, you will need:
1. Deoxidized annealed copper tube for refrigerant
tubing as detailed in Table 2.
Cut each tube to the appropriate l30 cm
to 40 cm to dampen vibration between units.
Table 2
2. Foamed polyethylene insulation for the specified
copper tubes as required to precise length of tub-
ing. Wall thickness of the insulation should be not
less than 8 mm.
3. Use insulated copper wire for field wiring. Wire
size varies with the total length of wiring. Refer to
3-6. Wiring Instructions for details.
Parts
Figure
1
1
2
AAA alkaline
battery
Remote
controller
Remote control
holder
Parts
Figure
Tapping
screw
Clamp
Tapping
screw
Truss-head
Phillips
4 30 mm
Truss-head
Phillips
4 16 mm
2
8
Air clean
filter
2
1
Parts
Figure
Packed in the indoor unit.
Q’ty
Q’ty
Q’ty
CAUTION
Check local electrical codes
and regulations before
obtaining wire. Also, check
any specified instructions or
limitations.
Model
Narrow Tube
Wide Tube
Outer Dia.
Thickness
Outer Dia.
Thickness
CS-ME7NKE
6.35 mm
0.8 mm
9.52 mm
0.8 mm
CS-ME9NKE
6.35 mm
0.8 mm
9.52 mm
0.8 mm
CS-ME12NKE
6.35 mm
0.8 mm
9.52 mm
0.8 mm
CS-ME18NKE
6.35 mm
0.8 mm
12.70 mm
0.8 mm
CS-ME24NKE
6.35 mm
0.8 mm
15.88 mm
1.0 mm
12-295 CU-5E34NBE_IU EN_3.qxd 2/27/12 4:35 PM Page 4
Содержание CS-ME12NKE
Страница 17: ...17 3 DIMENSIONAL DATA Indoor Unit CS ME7NKE CS ME9NKE CS ME12NKE Unit mm 852 0 0010 15500 0 ...
Страница 18: ...18 Indoor Unit CS ME18NKE CS ME24NKE Unit mm 852 0 0010 16200 0 ...
Страница 35: ......
Страница 36: ...Operating Instructions CS ME7NKE CS ME9NKE CS ME12NKE 852 6 4181 223 00 0 APPENDIX A A 1 ...
Страница 55: ...19 ...
Страница 73: ...37 ...
Страница 91: ...55 ...
Страница 109: ...73 ...
Страница 127: ...91 ...
Страница 145: ...109 ...
Страница 165: ......
Страница 166: ...Operating Instructions CS ME18NKE CS ME24NKE 852 6 4181 224 00 0 APPENDIX B A 2 ...
Страница 185: ...19 ...
Страница 203: ...37 ...
Страница 221: ...55 ...
Страница 239: ...73 ...
Страница 257: ...91 ...
Страница 275: ...109 ...
Страница 295: ......
Страница 437: ......
Страница 439: ......
Страница 440: ...DC1203 0 ...