– 40 –
CS-MA90KE
Servicing Information
●
By adding a jumper wire to the remote control side and a carbon resistor (1/4 W, 10 k
Ω
) to the indoor printed
circuit board, it is possible to select 4 types of transmission codes including one at time of delivery condition
(1).
Remote control
1
2
3
4
Switch SW B
↔
A
A
B
A
B
J – B
Jumper wire
Jumper wire
Indoor printed circuit board
Switch SW1
A
B
A
B
RX
10k
Ω
10k
Ω
Note
At product delivery
•
Remote Control Reset
When the batteries are inserted for the first time, or
the batteries are replaced, all the indications will
blink and the remote control might not work.
If this happens, remove the back cover of the remote
control and you will find a resetting terminal, and by
shorting it with a minus screwdriver, it will return to
normal.
•
Changing the wireless remote control transmis-
sion code
When two indoor units are installed in the same
room, in order to prevent operating errors caused by
using two remote controls, set up the remote control
[B
↔
A] switch (SW1).
The unit is set to A when it is shipped.
Reset terminal
SW1
A B
SW1
Remote Control
Remote Controller
B
A
B
A
Switch
Untitled-5
6/30/00, 8:14 AM
40