– 18 –
MAC9509078C2
CS-MA90KE
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during cooling operation.
• Fan speed rotates in the range of Hi to Me.
• Deodorizing Control.
Operation Details
Cooling Operation Time Diagram
Indoor
fan
Comp.
SLo
SLo
SLo
SLo
ON
ON
OFF
stop
stop
stop
30"
stop
30"
160"
1
40"
40"
20"
✕
...
.
2
✕
...
.
*
1 Fan Speed is Hi until the compressor stops (when the set temperature is reached).
*
2 Fan Speed is Me after the compressor restarts.
<Description of operation>
d – g
:
Time Delay Safety Control (waiting for 3 minutes)
g – h
:
60 sec. Forced Operation
h – o
:
7 min. Time Saved Control
q – t
:
Anti Freezing Control
a b c d e f g h i j k l m n o p q r s t u v w x y z
Basic time
Compressor
Indoor Fan
Outdoor Fan
Operation LED
4-way valve
1’
3’
1’
7’
1’
3’
4’
1.5˚C
ON
OFF
Comp.
Intake Air
Temperature
Comp.
Set Temp.
Indoor
Heat
Exchanger
Temp.
10°C
2°C
Stop
Operation
Untitled-5
6/30/00, 7:54 AM
18