– 26 –
MAC9509078C2
CS-MA90KE
Operation Details
6) Auto Restart Control
• If there is a power failure, operation will be automatically restarted when the power is resumed.
It will start with previous operation mode and airflow direction.
(Time Delay Safety Control is valid)
• Auto Restart Control is not available when Timer or Sleep Mode is set.
• This control can be omitted by cutting the jumper wire J2. (Refer Circuit Diagram)
7) Indoor Fan Motor Control
• Auto Fan Speed Control
When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the
table.
• Manual Fan Speed Control
Basic fan speed adjustment (3 settings, from Lo to Hi) can be carried out by using the Fan Speed selection button.
Fan Speed
No.
High Speed
↔
Low Speed
Cooling
Soft Dry
Heating
Voltage to Fan
Motor Drive
Transistor (V)
8
t
21.0
26.7
32.0
SHi
7
t
t
21.0
25.9
31.0
Hi
6
t
t
t
t
18.6
21.5
26.0
Me
5
t
t
t
17.0
18.1
22.5
Lo
4
t
t
t
t
15.8
15.8
21.5
Lo
–
3
t
t
t
t
11.0
11.0
16.5
SLo
2
11.0
11.0
11.0
MID
START
1
7.2
7.2
7.2
START
0
t
t
t
t
0
0
0
STOP
Manual
Auto
Sleep
Manual
Auto
Sleep
CS-MA70K
CS-MA90K
CS-MA120K
Untitled-5
6/30/00, 7:54 AM
26