– 46 –
CS-MA90KE
MAC9509078C2
30 32 34 36 38 40 42 44
OUTDOOR AIR TEMPERATURE (
°
C)
[Condition] Room temperature: 27/19
°
C
Cooling operation: At High fan
Piping length: 5 m
8
7
6
5
14
13
12
11
10
0.65
0.60
0.55
0.50
0.45
3.8
3.6
3.4
3.2
3.0
2.8
220V
240V
I: Q:
Current (A)
-
Cooling Capacity (kW)
-
LP: O: Outlet
Gas Side Piping Pressure (MPa)
-
Air Temperature (
°
C)
-
O
Q
I
L.P
Technical Data
L
L
L
L
L
Operation characteristics
CS-MA120KE / CU-MA240KE
The capability value shown is the value for one unit. For a total for two unit, multiply by 2.
-4 -2 0 2 4 6 8 10
OUTDOOR AIR TEMPERATURE (
°
C)
[Condition] Room temperature: 20
°
C
Heating operation: At High fan
Piping length: 5 m
7
6
5
4
44
42
40
38
36
34
1.8
1.7
1.6
1.5
1.4
1.3
5.0
4.5
4.0
3.5
3.0
220V
240V
I: Q:
Current (A)
-
Heating Capacity (kW)
-
HP: O: Outlet
Gas Side Piping Pressure (MPa)
-
Air Temperature (
°
C)
-
O
Q
I
L.P
1 5 10 15
PIPING LENGTH (m)
[Condition] Room temperature: 27/19
°
C
Outdoor temperature: 35/24
°
C
Cooling operation: At High fan
7
6
5
4
13
12
11
10
9
0.60
0.55
0.50
0.45
3.8
3.6
3.4
3.2
3.0
2.8
220V
240V
I: Q:
Current (A)
-
Cooling Capacity (kW)
-
LP: O: Outlet
Gas Side Piping Pressure (MPa)
-
Air Temperature (
°
C)
-
O
Q
I
L.P
•
Cooling Characteristic
•
Heating Characteristic
•
Piping Length Characteristic (Heating)
• Piping Length Characteristic (Cooling)
1 5 10 15
PIPING LENGTH (m)
[Condition] Room temperature: 20
°
C
Outdoor temperature: 7/6
°
C
Heating operation: At High fan
7
6
5
4
4.5
4.0
3.5
3.0
2.5
1.9
1.8
1.7
1.6
46
44
42
38
36
220V
240V
I: Q:
Current (A)
-
Heating Capacity (kW)
-
HP: O: Outlet
Gas Side Piping Pressure (MPa)
-
Air Temperature (
°
C)
-
O
Q
I
L.P
Untitled-6
6/30/00, 8:19 AM
46