DISPOSAL OF OUTDOOR UNIT DRAIN WATER
•
If a drain elbow is used, the unit should be placed on a
stand which is taller than 3 cm.
•
If the unit is used in an area where temperature falls below
0°C for 2 or 3 days in succession, it is recommended not to
use a drain elbow, for the drain water freezes and the fan
will not rotate.
CHECK THE DRAINAGE
•
Open front panel and remove air filters.
(Drainage checking can be carried out without removing the
front grille.)
•
Pour a glass of water into the drain tray-styrofoam.
•
Ensure that water flows out from drain hose of the indoor
unit.
EVALUATION OF THE PERFORMANCE
•
Operate the unit at cooling operation mode for fifteen
minutes or more.
•
Measure the temperature of the intake and discharge air.
•
Ensure the difference between the intake temperature and
the discharge is more than 8°C.
CHECK ITEMS
Is there any gas leakage at flare nut connections?
Has the heat insulation been carried out at flare nut
connection?
Is the connecting cable being fixed to terminal board firmly?
Is the connecting cable being clamped firmly?
Is the drainage OK?
(Refer to “Check the drainage” section)
Is the earth wire connection properly done?
Is the indoor unit properly hooked to the installation plate?
Is the power supply voltage complied with rated value?
Is there any abnormal sound?
Is the cooling operation normal?
Is the thermostat operation normal?
Is the remote control’s LCD operation normal?
Is the air purifying filter installed?
80
S-G95KE CU-G95KE / CS-G125KE CU-G125KE
Содержание CS-G125KE CU-G125KE
Страница 12: ...4 Dimensions 12 S G95KE CU G95KE CS G125KE CU G125KE ...
Страница 13: ...13 CS G95KE CU G95KE CS G125KE CU G125KE ...
Страница 14: ...5 Refrigeration Cycle Diagram 14 S G95KE CU G95KE CS G125KE CU G125KE ...
Страница 15: ...6 Block Diagram 15 CS G95KE CU G95KE CS G125KE CU G125KE ...
Страница 24: ... ii When indoor fan speed is lower than Medium 24 S G95KE CU G95KE CS G125KE CU G125KE ...
Страница 94: ...12 Technical Data 94 S G95KE CU G95KE CS G125KE CU G125KE ...
Страница 95: ...95 CS G95KE CU G95KE CS G125KE CU G125KE ...
Страница 109: ...109 CS G95KE CU G95KE CS G125KE CU G125KE ...
Страница 112: ...18 1 PRINT PATTERN INDOOR UNIT PRINTED CIRCUIT BOARD 112 S G95KE CU G95KE CS G125KE CU G125KE ...
Страница 113: ...18 2 PRINT PATTERN OUTDOOR UNIT PRINTED CIRCUIT BOARDBOTTOM VIEW 113 CS G95KE CU G95KE CS G125KE CU G125KE ...
Страница 114: ...114 S G95KE CU G95KE CS G125KE CU G125KE MACC Printed in Malaysia ...