Auto Vertical Airflow Direction Control
Heating
When the discharge air temperature is low such as at starts of heating op-
eration, the air blows at horizontal level.
As the temperature rises, the hot air blows in a downwards direction.
Cooling
●
Soft Dry
The louver swings up and down automatically.
AUTO
AUTO FAN
FAN SPEED
WIDE/SPOT
AIR SWING
TIMER
CLOCK
1
2
3
ON
OFF
SET
CANCEL
SLEEP
MODE
AUTO
Adjusting Airflow Direction and Fan Speed
Proper adjustment of airflow direction and fan speed increases operation
effectiveness.
Press FAN SPEED Button
●
There are five stages of fan speed in
addition to Auto Fan Speed.
Press
Button
●
There are seven positions of the horizontal airflow direction
louvers in additional to Auto Airflow Direction.
The display changes when the
button is pressed.
(The display does not show the exact directions of airflow or the
exact louver angles.)
To adjust the vertical airflow direction louvers
■
Auto Fan Speed Control
Heating
When the temperature of the discharge air
increases, the fan speed increases.
Cooling
●
Soft Dry
Changes the fan speed to generate a cool breeze. The air starts to blow out
approximately 40 seconds after the start of Cooling or Soft Dry.
To adjust fan speed
To adjust the horizontal airflow direction louvers
Auto Fan
Speed
Medium Fan
Speed
Display Example
COOL
COOL
AUTO FAN
AUTO FAN
COOL
COOL
h j k
Press
Button
●
There are five angles of vertical direction in addition to Auto Air-
flow Direction.
The display changes when the
button is pressed.
(The display indicates airflow direction.)
POWER
LOW
HIGH
SLEEP
TIMER
POWERFUL
POWER MONITOR
POWER
LOW
HIGH
SLEEP
TIMER
POWERFUL
POWER MONITOR
■
Auto Horizontal Airflow Direction Control
Heating
When air temperature is low, air is sent in WIDE. When temperature goes
up, air comes out in SPOT.
Cooling
●
Fan
Louvers swing horizontally at a fixed speed.
Soft Dry
Louvers are fixed to WIDE.
SPOT
WIDE
57
CS-G95KE CU-G95KE / CS-G125KE CU-G125KE
Содержание CS-G125KE CU-G125KE
Страница 12: ...4 Dimensions 12 S G95KE CU G95KE CS G125KE CU G125KE ...
Страница 13: ...13 CS G95KE CU G95KE CS G125KE CU G125KE ...
Страница 14: ...5 Refrigeration Cycle Diagram 14 S G95KE CU G95KE CS G125KE CU G125KE ...
Страница 15: ...6 Block Diagram 15 CS G95KE CU G95KE CS G125KE CU G125KE ...
Страница 24: ... ii When indoor fan speed is lower than Medium 24 S G95KE CU G95KE CS G125KE CU G125KE ...
Страница 94: ...12 Technical Data 94 S G95KE CU G95KE CS G125KE CU G125KE ...
Страница 95: ...95 CS G95KE CU G95KE CS G125KE CU G125KE ...
Страница 109: ...109 CS G95KE CU G95KE CS G125KE CU G125KE ...
Страница 112: ...18 1 PRINT PATTERN INDOOR UNIT PRINTED CIRCUIT BOARD 112 S G95KE CU G95KE CS G125KE CU G125KE ...
Страница 113: ...18 2 PRINT PATTERN OUTDOOR UNIT PRINTED CIRCUIT BOARDBOTTOM VIEW 113 CS G95KE CU G95KE CS G125KE CU G125KE ...
Страница 114: ...114 S G95KE CU G95KE CS G125KE CU G125KE MACC Printed in Malaysia ...