background image

4

Safety precautions

To prevent personal injury, injury to others or property 

damage, please comply with the following: 

Incorrect operation due to failure to follow instructions 

below may cause harm or damage, the seriousness of 

which is classified as below:

This appliance is filled with R32 (mild 

flammable refrigerant). If the refrigerant is 

leaked and exposed to an external ignition 

source, there is a risk of fire.

WARNING

This sign warns of death 

or serious injury.

CAUTION

This sign warns of injury 

or damage to property.

The instructions to be followed are classified by the 

following symbols:

This symbol denotes an action that 

is PROHIBITED.

These symbols denote actions 

COMPULSORY.

  

WARNING

Indoor unit and outdoor unit

This appliance is not intended for use by 

persons (including children) with reduced 

physical, sensory or mental capabilities, or lack 

of experience and knowledge, unless they have 

been given supervision or instruction concerning 

use of the appliance by a person responsible for 

their safety. Children should be supervised to 

ensure that they do not play with the appliance.

Be aware that refrigerant may not contain an 

odour, highly recommended to ensure suitable 

flammable refrigerant gas detectors are present, 

operating and able to warn of a leak.

Please consult authorised dealer or specialist to 

clean the internal parts, repair, install, remove 

and reinstall the unit. Improper installation and 

handling will cause leakage, electric shock or fire.

Confirm with authorised dealer or specialist on 

usage of any specified refrigerant type. 

Using refrigerant type other than the specified 

may cause product damage, burst and injury etc.
Do not use means to accelerate the defrosting 

process or to clean, other than those 

recommended by manufacturer. Any unfit 

method or using incompatible material may 

cause product damage, burst and serious injury.

Do not pierce or burn as the appliance is 

pressurized. Do not expose the appliance to 

heat, flame, sparks, or other sources of ignition. 

Else it may explode and cause injury or death.

Do not install the unit in a potentially explosive 

or flammable atmosphere. Failure to do so could 

result in fire.

Do not insert your fingers or other objects 

into the air conditioner indoor or outdoor 

unit, rotating parts may cause injury.

Do not touch the outdoor unit during lightning, it 

may cause electric shock.

Do not expose yourself directly to cold air for a 

long period to avoid excess cooling.

Do not sit or step on the unit, you may 

fall down accidentally.

Indoor unit

Outdoor unit

Power supply

Remote control

Air inlet

Air inlet

Air outlet

Air outlet

The appliance shall be installed, and/or operated 

in a room  and 

 flame or hazardous 

 appliances, gas cooking, 

from ignition sources,

sparks/open

gas

keep away

such as heat/

areas such as 

reticulated gas appliances, etc.

Содержание CS/CU-HU12ZKY Series

Страница 1: ...fore installation the installer should Read the Installation Operating Instructions then request the customer keep them for future reference Remove the remote control packed with the indoor unit Air c...

Страница 2: ...INVERTER leverages ECONAVI sensor data and varies compressor rotation speed This helps to optimize cooling operation and reduces wasteful cooling nanoe G nanoeX Purifies the air down to the smallest p...

Страница 3: ...FAN DRY 2 1 3 7m Accessories Remote control AAA or R03 batteries X 2 Remote control holder Screws for remote control holder X 2 Ag Clean PM 0 1 Filter Safety precautions 4 9 How to use 10 11 To learn...

Страница 4: ...pecialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handling will cause leakage electric shock or fire Confirm with authorised dealer or specia...

Страница 5: ...the same as conventional refrigerant R410A R22 models Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especi...

Страница 6: ...accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as...

Страница 7: ...where they are unlikely to be exposed to any substance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being co...

Страница 8: ...nd during the brazing process 8 Removal and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important...

Страница 9: ...hat it has been de commissioned and emptied of refrigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Rec...

Страница 10: ...ling operation Vertical flaps will not work in AUTO air swing in HU and AU18 4F Model FAN To operate Air Con in Fan Only mode Indoor unit temp display will show set temp for AUTO COOL DRY mode and roo...

Страница 11: ...ally after 1 hour JETSTREAM To set the timer To turn ON and OFF the unit at a preset time To enjoy freshness and cleaner environment This is a combination operation together with nanoeX and nanoe G na...

Страница 12: ...ow activity to maximise energy saving Mode Human Low activity COOL Set temperature ECONAVI take advantage of the human nature that human being takes time to feel the temperature rise during low activi...

Страница 13: ...native to remove moisture left in the internal parts thoroughly to prevent mould growth Turn off the power supply and unplug Remove the remote control batteries nanoe G Generator For better efficiency...

Страница 14: ...and some alpha numeric codes appear on IDU display Unit s Wi Fi connection with the router is activated Wi Fi LED stays ON during unit turn OFF Check unit s Wi Fi connection with router Wi Fi LED coun...

Страница 15: ...Note 15 English Troubleshooting...

Страница 16: ...e condenser is not obstructed There should not be any animal or plant which could be affected by hot air discharged Keep the spaces indicated by arrows from wall ceiling fence or other obstacles Do no...

Страница 17: ...and secure with vinyl tape Vinyl tape Insulation of piping connections Remote control holder Remote control holder xing screws Remote control Attaching the remote control holder to the wall 50 mm or m...

Страница 18: ...uld be about from this line 1 Mount the installation plate on the wall with 5 screws or more at least 5 screws If mounting the unit on the concrete wall consider using anchor bolts Always mount the in...

Страница 19: ...left piping Right Rear piping Cover for piping How to keep the cover In case of the cover is cut keep the cover at the rear of chassis as shown in the illustration for future reinstallation Left right...

Страница 20: ...n cable Gas side piping Liquid side piping Drain hose Insert the connection cable This can be used for left rear piping and bottom piping also How to pull the piping and drain hose out in case of the...

Страница 21: ...roprene sheathed 4 x 1 0 mm2 1 5 1 8HP 4 x 1 5 mm2 2 0HP or 4 x 2 5mm2 2 5HP exible cord type designation IS 694 or 60245 IEC 57 or heavier cord Bind all the indoor and outdoor connection cable with t...

Страница 22: ...n this area must follow to national wiring rules Do not joint wires Wire stripping No loose strand when inserted 10 1 mm Conductor fully inserted ACCEPT Conductor over inserted PROHIBITED Conductor no...

Страница 23: ...ated in the table Torque wrench Spanner or Wrench Decide piping length and then cut by using pipe cutter Remove burrs from cut edge Make are after inserting the are nut locate at valve onto the copper...

Страница 24: ...r unit and outdoor unit shall be approved polychloroprene sheathed 4 x 1 0 mm2 1 5 1 8HP 4 x 1 5 mm2 2 0HP or 4 x 2 5mm2 2 5HP exible cord type designation IS 694 or 60245 IEC 57 or heavier cord Do no...

Страница 25: ...wn in the illustration 3 Then remove the 2 1 5HP or 4 2 0 2 5HP mounting screws 4 Pull the lower section of the front grille towards you to remove the front grille The below operations will be perform...

Страница 26: ...insulating material with a new one Heat insulating material is required for both liquid side and gas side piping Most Important Process Purpose To make the oil refrigerant mix together They are in se...

Страница 27: ...n inside a building or dwelling or room must be made by brazing orwelding Joint connection of indoor unit by aring method can only be made at outdoor or at outside of a buidling or dwelling or room Fl...

Страница 28: ...b 17 C for Half Load 50 For Full Load QUIET CLEAN Open the Front Panel by lifting Intake Grille Follow the below Instructions 4 Air Swing Horizontal Airflow Set vane position to be AUTO 5 Fan speed M...

Страница 29: ...r Unit Control button while holding the indoor unit button Step b Within 5 second press once the Remote Step c After hearing a beep sound from the Indoor Unit immediately release the Auto OFF ON butto...

Страница 30: ...ranty for 3 years from the date of purchase Product ROOM AIR CONDITIONER Panasonic Life Solutions India Pvt Ltd Model No ODU SI No IDU SI No Customer Name Address Tel No Date of Purchase Invoice No De...

Страница 31: ...re eg Rat lizard insect ants etc inside the Product unit f Use of harmful chemicals Improper heat load Usage of unit in an abnormally corrosive alkaline acidic atmosphere g Any change or defect result...

Страница 32: ...m in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should b...