Panasonic CS/CU-HU12ZKY Series Скачать руководство пользователя страница 12

12

To learn more...

To select different Performance modes 

The human activity sensor will also scan for area of heat source and movement in a room.

Detection area

• Based on area activeness horizontal airflow direction will adjust either fix 

at predetermined position or swing left/right periodically. 

This will be applicable only when Unit Horizontal Airflow is Set in Auto Swing 

 position.

• The human activity sensor performance is influenced by indoor unit 

location, movement speed, temperature range, etc.

120°

7m

• The human activity sensor may: 

-  mistakenly detect an object with heat source & movement similar to human, such as pets, etc. 

-  mistakenly detect as non-heat source & movement if a human stays motionless for certain period of time.

• Do not place large objects near the sensor and keep away heating units or humidifier from the sensor’s detection 

area. They may cause sensor malfunction.

* ECONAVI

The unit will start to initialise

(for approximately 1 minute)

The human activity sensor 

will start to detect.

Human activity sensor operation

ECONAVI

 ; Detecting human presence and activity, the unit controls room temperature to save energy.

Mode 

Human

Low activity

Normal activity

High activity

Absent

COOL

Set 

temperature

+1°C

+2°C

ECONAVI

Precise control of temperature during low activity to maximise energy saving.

Mode 

Human

Low activity

COOL

Set 

temperature

ECONAVI take advantage of the human nature that 

human being takes time to feel the temperature rise 

during low activity level; the unit adjusts temperature to 

maximise energy saving without sacrificing the comfort.

Note:

 

* Not applicable for “WU”, “XU”, “PU” & “AU” series.

This operation Changes Air Conditioner Performance in COOL Mode only.

converti7

• Step 1 : “

HC

” is display on Unit and Remote. Unit will operate in High Capacity Mode.

• Step 2 : “

FC

” is display on Unit and Remote. Unit Input Power will be upto 100%.

• Step 3 : “

90

” is display on Unit and Remote. Unit Input Power will be upto 90%.

• Step 4 : “

80

” is display on Unit and Remote. Unit Input Power will be upto 80%.

• Step 5 : “

  

” is display on Unit and Remote. Unit Input Power will be upto 70%.

• Step 6 : “

55

” is display on Unit and Remote. Unit Input Power will be upto 55%.

• Step 7 : “

40

” is display on Unit and Remote. Unit Input Power will be upto 40%.

• Press “

converti7

” button again to exit from this feature.

• Set temperature will display about 5 sec. if press fan speed button or change temperature.

• User can select Fan speed as per need.

• Capacity may decrease when “

converti7

” mode is Selected.

• Capacity measurement is done Under Standard Lab condition and may vary based on Ambient 

  Temperature and Room Size.

• JETSTREAM, ECONAVI, SLEEP will not work in this mode and vice versa.

• “

AI

” mode is Applicable for Models having Wi-Fi Feature and it will be Accessible through MirAIe APP only.

Содержание CS/CU-HU12ZKY Series

Страница 1: ...fore installation the installer should Read the Installation Operating Instructions then request the customer keep them for future reference Remove the remote control packed with the indoor unit Air c...

Страница 2: ...INVERTER leverages ECONAVI sensor data and varies compressor rotation speed This helps to optimize cooling operation and reduces wasteful cooling nanoe G nanoeX Purifies the air down to the smallest p...

Страница 3: ...FAN DRY 2 1 3 7m Accessories Remote control AAA or R03 batteries X 2 Remote control holder Screws for remote control holder X 2 Ag Clean PM 0 1 Filter Safety precautions 4 9 How to use 10 11 To learn...

Страница 4: ...pecialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handling will cause leakage electric shock or fire Confirm with authorised dealer or specia...

Страница 5: ...the same as conventional refrigerant R410A R22 models Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especi...

Страница 6: ...accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as...

Страница 7: ...where they are unlikely to be exposed to any substance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being co...

Страница 8: ...nd during the brazing process 8 Removal and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important...

Страница 9: ...hat it has been de commissioned and emptied of refrigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Rec...

Страница 10: ...ling operation Vertical flaps will not work in AUTO air swing in HU and AU18 4F Model FAN To operate Air Con in Fan Only mode Indoor unit temp display will show set temp for AUTO COOL DRY mode and roo...

Страница 11: ...ally after 1 hour JETSTREAM To set the timer To turn ON and OFF the unit at a preset time To enjoy freshness and cleaner environment This is a combination operation together with nanoeX and nanoe G na...

Страница 12: ...ow activity to maximise energy saving Mode Human Low activity COOL Set temperature ECONAVI take advantage of the human nature that human being takes time to feel the temperature rise during low activi...

Страница 13: ...native to remove moisture left in the internal parts thoroughly to prevent mould growth Turn off the power supply and unplug Remove the remote control batteries nanoe G Generator For better efficiency...

Страница 14: ...and some alpha numeric codes appear on IDU display Unit s Wi Fi connection with the router is activated Wi Fi LED stays ON during unit turn OFF Check unit s Wi Fi connection with router Wi Fi LED coun...

Страница 15: ...Note 15 English Troubleshooting...

Страница 16: ...e condenser is not obstructed There should not be any animal or plant which could be affected by hot air discharged Keep the spaces indicated by arrows from wall ceiling fence or other obstacles Do no...

Страница 17: ...and secure with vinyl tape Vinyl tape Insulation of piping connections Remote control holder Remote control holder xing screws Remote control Attaching the remote control holder to the wall 50 mm or m...

Страница 18: ...uld be about from this line 1 Mount the installation plate on the wall with 5 screws or more at least 5 screws If mounting the unit on the concrete wall consider using anchor bolts Always mount the in...

Страница 19: ...left piping Right Rear piping Cover for piping How to keep the cover In case of the cover is cut keep the cover at the rear of chassis as shown in the illustration for future reinstallation Left right...

Страница 20: ...n cable Gas side piping Liquid side piping Drain hose Insert the connection cable This can be used for left rear piping and bottom piping also How to pull the piping and drain hose out in case of the...

Страница 21: ...roprene sheathed 4 x 1 0 mm2 1 5 1 8HP 4 x 1 5 mm2 2 0HP or 4 x 2 5mm2 2 5HP exible cord type designation IS 694 or 60245 IEC 57 or heavier cord Bind all the indoor and outdoor connection cable with t...

Страница 22: ...n this area must follow to national wiring rules Do not joint wires Wire stripping No loose strand when inserted 10 1 mm Conductor fully inserted ACCEPT Conductor over inserted PROHIBITED Conductor no...

Страница 23: ...ated in the table Torque wrench Spanner or Wrench Decide piping length and then cut by using pipe cutter Remove burrs from cut edge Make are after inserting the are nut locate at valve onto the copper...

Страница 24: ...r unit and outdoor unit shall be approved polychloroprene sheathed 4 x 1 0 mm2 1 5 1 8HP 4 x 1 5 mm2 2 0HP or 4 x 2 5mm2 2 5HP exible cord type designation IS 694 or 60245 IEC 57 or heavier cord Do no...

Страница 25: ...wn in the illustration 3 Then remove the 2 1 5HP or 4 2 0 2 5HP mounting screws 4 Pull the lower section of the front grille towards you to remove the front grille The below operations will be perform...

Страница 26: ...insulating material with a new one Heat insulating material is required for both liquid side and gas side piping Most Important Process Purpose To make the oil refrigerant mix together They are in se...

Страница 27: ...n inside a building or dwelling or room must be made by brazing orwelding Joint connection of indoor unit by aring method can only be made at outdoor or at outside of a buidling or dwelling or room Fl...

Страница 28: ...b 17 C for Half Load 50 For Full Load QUIET CLEAN Open the Front Panel by lifting Intake Grille Follow the below Instructions 4 Air Swing Horizontal Airflow Set vane position to be AUTO 5 Fan speed M...

Страница 29: ...r Unit Control button while holding the indoor unit button Step b Within 5 second press once the Remote Step c After hearing a beep sound from the Indoor Unit immediately release the Auto OFF ON butto...

Страница 30: ...ranty for 3 years from the date of purchase Product ROOM AIR CONDITIONER Panasonic Life Solutions India Pvt Ltd Model No ODU SI No IDU SI No Customer Name Address Tel No Date of Purchase Invoice No De...

Страница 31: ...re eg Rat lizard insect ants etc inside the Product unit f Use of harmful chemicals Improper heat load Usage of unit in an abnormally corrosive alkaline acidic atmosphere g Any change or defect result...

Страница 32: ...m in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should b...

Отзывы: