39
12.5.2 OFF Timer Control
OFF timer 1 and OFF timer 2 can be set using remote control, the unit with timer set will stop operate at set time.
12.6 Auto Restart Control
1 When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within
three to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be
selected randomly) after power supply resumes.
2 This type of control is not applicable during ON/OFF Timer setting.
3 This control can be omitted by open the circuit of JP1 at indoor unit printed circuit board.
12.7 Indication Panel
LED POWER/DEICE
TIMER
Color Green Blue
Orange
Light ON
Operation ON
Deice Operation
Time Setting ON
Light OFF
Operation OFF
Time Setting OFF
Note:
•
If POWER LED is blinking, the possible operation of the unit are Hot Start, operation mode judgment, or ON timer
sampling.
•
If Timer LED is blinking, there is an abnormality operation occurs.