28
11.2.3 Indoor Unit Installation
11.2.3.1
For the right rear piping
Step-1
Pull out the Indoor piping
Step-2
Install the Indoor Unit
Step-3
Secure the Indoor Unit
Step-4
Insert the connection cable
11.2.3.2
For the right and right bottom
piping
Step-1
Pull out the Indoor piping
Step-2
Install the Indoor Unit
Step-3
Insert the connection cable
Step-4
Secure the Indoor Unit
11.2.3.3
For the embedded piping
• Use a spring bender or equivalent to bend the
piping so that the piping is not crushed.
Step-1
Replace the drain hose
Step-2
Bend the embedded piping
Step-6
Connect the piping
Step-3
Pull the connection cable into Indoor Unit
Step-4
Cut and
fl
are the embedded piping
• The inside and outside connection cable can be
connected without removing the front grille.
Step-5
Install the Indoor Unit
• When determining the dimensions of the piping,
slide the unit all the way to the left on the
installation plate.
• Refer to the section “Cutting and
fl
aring the
piping”.
• Please refer to “Connecting the piping” column in
outdoor unit section. (Below steps are done after
connecting the outdoor piping and gas-leakage
con
fi
rmation.)
Step-7
Insulate and
fi
nish the piping
Step-8
Secure the Indoor Unit
• Please refer to “Insulation of piping
connection” column as mentioned in
indoor/outdoor unit installation.
Cover for piping
In case of the cover is cut, keep
the cover at the rear of chassis as
shown in the illustration for future
reinstallation.
(Left, right and 2 bottom covers for
piping.)
How to keep the cover
Guide
surface
Connection cable
Ab
ou
t
70
– 8
0 m
m
Connection cable
Gas side
piping
Liquid side
piping
Drain hose
Insert the connection cable
Install the indoor unit
Hook the indoor unit onto the
upper portion of installation
plate. (Engage the indoor unit
with the upper edge of the
installation plate). Ensure the
hooks are properly seated
on the installation plate by
moving it in left and right.
Drain hose
Sleeve for
piping hole
Indoor unit
Hooks at
installation
plate
Piping
To take out the unit, push
the
marking at the
bottom unit, and pull it slightly
towards you to disengage the
hooks from the unit.
g
n
i
k
r
a
m
1. Press the lower left and right side
of the unit against the installation
plate until hooks engages with their
slot (sound click).
Secure the Indoor Unit
Installation
plate
Unit’s
hook
Right Rear piping
Cover for the
bottom piping
Cover for the
bottom piping
Tape it with
piping in a position as
mentioned in
Fig. below.
Cover for
the right
piping
Piping
Drain
hose
Cover
for the
left
piping
Cover for the
bottom piping
Tape it with piping in a
position as mentioned in
Fig. below.
Cover for
the right
piping
Piping
Drain hose
Cover for
the left
piping
Right and Right Bottom piping
(This can be used for left rear piping and bottom
piping also.)