12.1.5 Automatic
Operation
•
This mode can be set using remote control and the operation is decided by remote control setting temperature,
remote control operation mode and indoor intake air temperature.
•
During operation mode judgment, indoor fan motor (with speed of Lo-) is running for 30 seconds to detect the
indoor intake air temperature.
•
Every 10 minutes, the indoor temperature is judged.
•
For the 1st judgment
o
If indoor intake temperature - remote control setting temperature
≥
2°C, COOL mode is decided.
o
If
-2°C
≤
indoor intake temperature - remote control setting temperature < 2°C, DRY mode is decided.
o
If indoor intake temperature - remote control setting temperature < -2°C, HEAT mode is decided.
Heat
Dry
Cool
-6
-5
-4
-3
-1
0
4
6
5
3
2
1
-2
•
For the 2nd judgment onwards
o
If indoor intake temperature - remote control setting temperature
≥
3°C, if previous operate in DRY mode,
then continue in DRY mode. otherwise COOL mode is decided.
o
If
-2°C
≤
indoor intake temperature - remote control setting temperature < 3°C, maintain with previous mode.
o
If indoor intake temperature - remote control setting temperature < -2°C, HEAT mode is decided.
Heat
Maintain
current mode
Cool
/Dry
-6
-5
-4
-3
-2
-1
0
4
6
5
2
3
1
12.1.6 Fan
Operation
•
Fan Operation is used to circulate air in a room.
•
During operation, indoor fan run continuously but outdoor fan and compressor stop.
•
Temperature setting is not applicable.
12.2 Indoor Fan Motor Operation
A. Basic Rotation Speed (rpm)
i. Manual Fan Speed
[Cooling, Dry, Fan]
•
Fan motor’s number of rotation is determined according to remote control setting.
Remote
control
O O O O O
Tab Hi
Me+
Me
Me-
Lo
[Heating]
•
Fan motor’s number of rotation is determined according to remote control setting.
Remote
control
O O O O O
Tab SHi
Me+
Me
Me-
Lo