G
Electronic shutter synchro scan setting [Synchro Scan: 60.34 Hz to 15.75 kHz]
This can be set only when “Synchro scan” has been selected as the electronic shutter
speed selection
F
setting. The horizontal bar noise can be reduced by adjusting the
synchro scan frequency when shooting the screen of a work station, etc.
Refer to the table below for the light quantity that should be set at different shutter
speeds and synchro scan frequencies.
H
Image (CCD readout method) selection [V Resolution: Normal or fine]
Normal:
Normal image. (Field storage is used as the CCD storage method.)
Fine:
The vertical resolution is improved. (It is improved by frame storage and the
electronic shutter with no accompanying increase in the residual image.)
I
PC control communication speed selection [Baud Rate: 1200, 2400, 4800 or 9600
bps]
This is for selecting the baud rate at which the camera is to be controlled from a
computer.
J
Negative/positive selection [Nega/Posi: Posi or Nega]
Posi:
Normal images.
Nega:
Images whose light and dark sections and colors are reversed.
<Note>
Negative images are shown only for composite outputs and Y/C outputs when the option
cards are used.
Menu Item Settings and Changes
(in halogen light mode, fluorescent light mode or outdoor mode)
Shutter speed
Synchro scan
frequency
Light quantity
ratio required
OFF
==
1
1/100
99.68Hz
2
1/250
250.0Hz
4
1/500
492.2Hz
8
1/1000
984.4Hz
16
1/2000
1.969kHz
32
1/4000
3.938kHz
64
1/10000
7.875kHz
160