Installation Instructions
Before installation, always disconnect the DC
connector
When installing, always use the supplied components.
Do not disassemble or modify the wall mount adaptor.
Tightening up the mounting screws
• Tighten up the screws and bolts securely to the degree that is
appropriate for each of the materials used in the mounting location
and structures.
•
After tightening up the screws and bolts, check that there is no
unsteadiness and that the parts have been tightened securely.
•
Use the specified tools and tighten the screws firmly.
•
Tighten up the screws using the specified torque driver. Do not
use electrical drivers or impact drivers.
When the unit is no longer going to be used, do
not leave it lying around, but be absolutely sure
to dispose of it properly.
For details on how to remove the unit, refer to “Removing the
camera” (→ page 14).
When installing, transferring or disposing of
the unit, be absolutely sure to hold it by its
pedestal area.
Problems may result if the camera head is held or rotated.
Do not attach a filter, hood, extender or other
parts to the unit.
Install the external DC power supply near the
main power outlet, and position it in such a
way that its power plug can be plugged into
and unplugged from the outlet easily.
When connecting the external DC power supply to a power outlet on
the ceiling or on any other surface where dust may collect, wipe off
the dust on the power plug at periodic intervals as an anti-tracking
measure.
Power switch
This unit does not have a power switch. When the power
is supplied, the pan, tilt, zoom and focusing operations are
performed.
*
1
Before proceeding with maintenance, be absolutely
sure to disconnect the power plug from the power outlet.
*
1
• Under factory default conditions, the unit will be in Standby
mode when power is supplied for the first time. (Status display
lamp: Lit orange)
• When the power supply is cut off while the unit is in Standby
mode, the unit will be in Standby mode the next time power is
supplied. (Status display lamp: Lit orange)
•
When the power supply is cut off while the unit is in Power ON
mode, the unit will be in Power ON mode the next time power
is supplied. (Status display lamp: Lit green)
(For details, refer to “How to turn the power on and off”
(→ page 59).)
Grounding
Before operating the unit, check that SIGNAL GND has been
securely grounded.
If there is a possibility of noise interference
Either wire the cables so that the power cable (ceiling light cord) of
AC 100 V
*
2
(AC 220 V
*
3
) or more, and the signal cable are placed
at least 1 meter (3.3 ft) apart.
Alternatively run each cable through its own metal conduit.
(The metal conduits must be grounded.)
*
2
For AW-UE150WP, AW-UE150KP
*
3
For AW-UE150WE, AW-UE150KE
Radio signal interference
If the unit is positioned near a TV or radio transmitting antenna or a
strong electrical field or magnetic field (such as that generated by a
motor, transformer or power lines), its images may be distorted and/
or the images may be affected by noise.
When connecting the cables, ensure that the
connector areas will not be subject to any load.
Doing so may cause malfunctioning.
Allowing the generated heat to escape
This unit allows the heat generated inside to escape from its
surfaces.
Do not install the unit in a location where it will be surrounded by
walls or other surfaces and where heat will be trapped.
In addition, the heat is dissipated to the bottom panel which will
warm up over time: This is normal and not indicative of any trouble.
PoE++ power supplies
Use a PoE++ [IEEE802.3bt Draft ver.2.0 standard (LLDP not
supported)] compatible hub or power supply device.
Network settings
The network function of this unit does not work unless an initial
account is set up (except when using the Easy IP Setup Software
(→ page 57)). A personal computer is required to set up an initial
account. (→ page 58)
<NOTE>
•
Network connection with AW-RP150 also requires setup of an
initial account. When an initial account is not set up, AW-RP150
can detect but cannot control this unit.