
45 (E)
5. External device control interfaces
5-1. LAN connection
Use LAN cables to connect the AW-HE50, AW-RP50 and host computer.
When connecting the unit directly to another device, use a crossover cable.
For network connections via a device such as a hub (switching hub), use straight cables.
When a hub is not going to be used, ensure that the length of the LAN cable does not exceed 100 meters (when a cable of
category 5 or above is used).
For further details on the AW-HE50 and AW-RP50 connections and settings, refer to “2-2-2. Example of connections”
(<Basics> Operating Instructions).
For details on the functions available when connection has been made to the host computer, refer to “6. Connections with a
computer”.
5-2. TALLY/GPI
The TALLY/GPI connector features five contact input ports
for controlling the unit from an external device and seven
open collector output ports for outputting the tally and status
information from the unit to an external device.
(D-sub 15-pin, female, inch thread)
8
1
15
9
Pin
No.
Signal
Input/output
Details of signal
Operation
1
TALLY OUT1
Open collector output
Tally output of input image 1
A low-level signal is output during tally
output.
2
TALLY OUT2
Open collector output
Tally output of input image 2
3
TALLY OUT3
Open collector output
Tally output of input image 3
4
TALLY OUT4
Open collector output
Tally output of input image 4
5
TALLY OUT5
Open collector output
Tally output of input image 5
6
ALARM
Open collector output
Fan alarm or power alarm output
A low-level signal is output when trouble
has occurred.
7
KEY ON
Open collector output
Key combination status output
A low level is output during key
combinations.
8
(RESERVE)
Contact input
(Reserve)
9
NC
Not used
10
Tally Disable
Contact input
Tally signal enable/disable
This signal is enabled by the contact
input (and disabled when open).
11
AUTO
Contact input
AUTO button of transition part
The signal is made operational by the
contact input (30 ms or more).
12
CUT
Contact input
CUT button of transition part
13
KeyON
Contact input
KEY ON button of transition part
14
PinPON
Contact input
PinP button of transition part
15
GND
Ground
Ground
GND
TALLY OUT1 – 5
ALARM
KEY ON
Tally LED
Example of an open collector output connection
Ensure that the conditions given below are satisfied.
Dielectric strength: Max. DC 24 V
Current:
Max. 50 mA
AW-HS50
(Max. voltage: 24 V)
(Max. current: 50 mA)
GND
Tally Disable
AUTO
CUT
KeyON
PinPON
+3.3 V
Example of a contact input connection
Provide contact inputs.
AW-HS50
Содержание AW-HS50E
Страница 67: ...Memo ...
Страница 199: ...Notes ...
Страница 265: ...Appunti ...
Страница 331: ...Apuntes ...
Страница 397: ...Памятка ...
Страница 398: ...F0610Y1070 D Panasonic System Networks Co Ltd 2010 ...