30 (E)
ENGLISH
2. Input/output signal settings
[10.3] Input Menu/SDI-IN3
10.
UC:Mvdet/Sharp
[10.4] Input Menu/SDI-IN4
10.
UC:Mvdet/Sharp
Mvdet:
This is used to set the motion detection sensitivity of
the image.
1
2
3
4
5
Toward still images
Standard
Toward moving images
Sharp:
This is used to enhance the sharpness of the image
edges.
1
2
3
4
5
Not sharp edges
Standard
Very sharp edges
2-1-8. Setting the input image scaling
[10.5] Input Menu/DVI-IN
4.
Scale
This is used to set the scaling for the DVI-D input signal
images.
Listed below are the resolutions of the images which can be
input.
Resolutions supported
XGA
1024
768/60 Hz
WXGA
1280
768/60 Hz
SXGA
1280
1024/60 Hz
WSXGA+
1680
1050/60 Hz
UXGA
1600
1200/60 Hz
WUXGA
1920
1200/60 Hz
1080/59.94p
1920
1080/59.94 Hz
1080/50p
1920
1080/50 Hz
Select the scaling method from among the options listed
below.
Fit-V
The aspect ratio of the input image is
maintained, and the size of the image is
enlarged or reduced in accordance with the
vertical resolution.
Fit-H
The aspect ratio of the input image is
maintained, and the size of the image is
enlarged or reduced in accordance with the
horizontal resolution.
FULL
The size of the image is enlarged or reduced in
accordance with the system resolution.
The aspect ratio of the image is not
maintained.
The enlargement and reduction ratios
differ between the horizontal and vertical
directions.
For details on which sizes are supported for which
formats, refer to “Table of DVI input scaling sizes” on
the next page.
Содержание AW-HS50E
Страница 67: ...Memo ...
Страница 199: ...Notes ...
Страница 265: ...Appunti ...
Страница 331: ...Apuntes ...
Страница 397: ...Памятка ...
Страница 398: ...F0610Y1070 D Panasonic System Networks Co Ltd 2010 ...