Max bit rate (per client)
Specify the H.264 bit rate per client.
When [Transmission priority] is set to [Best effort], specify the
maximum and minimum but rate.
Setting value:
64kbps/128kbps
*
1
/256kbps
*
1
/384kbps
*
1
/512kbps
*
1
/
768kbps
*
1
/1024kbps
*
1
/1536kbps
*
1
/2048kbps
*
1
/3072kbps
*
1
/
4096kbps
*
1
/6144kbps
*
1
/8192kbps
*
1
/10240kbps
*
1
/
12288kbps
*
1
/14336kbps
*
1
/16384kbps
*
1
/20480kbps
*
1
/
24576kbps
*
1
Factory settings:
H.264(1): 4096kbps
H.264(2): 1536kbps
H.264(3): 1024kbps
H.264(4): 512kbps
The range of H.264 bit rates that can be specified varies depending
on the resolution.
• 160 × 90: 64kbps to 2048kbps
• 320 × 180, 640 × 360: 64kbps to 4096kbps
• 1280 × 720: 256kbps to 8192kbps
• 1920 × 1080: 512kbps to 14336kbps
• 1920 × 1080 (60fps), 1280 × 720 (60fps):
1024kbps to 24576kbps
*
1
The H.264 bit rate is limited by the [Bandwidth control (bitrate)]
(→ page @@) setting under the [Network] tab of the Network
screen. The actual bit rate may be lower than the specified value.
Image quality
Select the image quality for H.264 images.
Setting value:
Low(Motion priority) / Normal / Fine(Image quality priority)
Factory settings:
Normal
<NOTE>
• This setting is only enabled when [Transmission priority] (→ page
@@) is set to [Constant bit rate] or [Best effort].
Refresh interval
Select the refresh interval for H.264 images (I-frame interval: 0.2 to 5
seconds).
If errors occur frequently in the network environment, decreasing the
refresh interval will reduce image distortions.
However, the frame rate may decrease.
Setting value:
For 60Hz:
0.2s / 0.25s / 0.33s / 0.5s / 1s / 2s / 3s / 4s / 5s
For 50Hz:
0.2s / 0.5s / 1s / 2s / 3s / 4s / 5s
Factory settings:
1s
Transmission type
Select the transmission format for H.264 images.
Setting value:
Unicast port
(AUTO)
Up to 24 users can access a single camera at the
same time.
[Unicast port1 (Image)] and [Unicast port2
(Audio)] will be configured automatically when
images and audio are sent from the camera.
We recommend selecting the [Unicast port
(MANUAL)] setting when the port number
transmitting the H.264 images does not need to
be fixed (e.g., during use within a network).
Unicast port
(MANUAL)
Up to 24 users can access a single camera at the
same time.
[Unicast port1 (Image)] and [Unicast port2
(Audio)] must be configured manually when
images and audio are sent from the camera.
When transmitting H.264 images via the
Internet, configure a fixed transmission port for
the broadband router (hereafter referred to as
"router") (→ page @@). For details, refer to the
operating instructions for the router.
Multicast port
An unlimited number of users can access a single
camera at the same time.
When transmitting H.264 images via multicast,
enter the [Multicast address], [Multicast port], and
[Multicast TTL/HOPLimit].
Factory settings:
Unicast port (AUTO)
<NOTE>
• For details on the maximum number for simultaneous access, see
page @@.
Unicast port1 (Image)
*
1
Enter the unicast port number (used when sending images from the
unit).
Usable port number range:
1024 to 50000
• Only even numbers can be specified.
• The port number cannot be set to 10670.
Factory settings:
H.264(1): 32004
H.264(2): 32014
H.264(3): 32024
H.264(4): 32034
*
1
The unicast port number must be configured when [Transmission
type] is set to [Unicast port (MANUAL)].
Unicast port2 (Audio)
*
1
Usable port number range:
1024 to 50000
• Only even numbers can be specified.
• The port number cannot be set to 10670.
Factory settings:
H.264(1): 32004
H.264(2): 32014
H.264(3): 32024
H.264(4): 32034
*
1
The unicast port number must be configured when [Transmission
type] is set to [Unicast port (MANUAL)].
74
75
Web screen configurations (continued)
Содержание AW-HE130KE
Страница 124: ...Index 124 ...