AV6 (CS) Subminiature Switches
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
2
© Panasonic Corporation 2019
AECTB60E 201903
SPECIFICATIONS
■ Contact rating
■ Characteristics
■ Operating characteristics
PRODUCT TYPES
■ Lever position: Standard
Actuator
Operating Force (OF) Max.
Contact form
SPST-NC
SPST-NO
Pin plunger
0.50N
AV620264
AV630264
1.50N
AV620564
AV630564
Hinge lever
0.20N
AV622264
AV632264
0.50N
AV622564
AV632564
Simulated roller lever
0.20N
AV624264
AV634264
0.50N
AV624564
AV634564
Roller lever
0.20N
AV625264
AV635264
0.50N
AV625564
AV635564
■ Lever position: Backward
Actuator
Operating Force (OF) Max.
Contact form
SPST-NC
SPST-NO
Hinge lever
0.35N
AV62221264
AV63221264
1.00N
AV62251264
AV63251264
Simulated roller lever
0.35N
AV62421264
AV63421264
1.00N
AV62451264
AV63451264
Roller lever
0.35N
AV62521264
AV63521264
1.00N
AV62551264
AV63551264
Contact
Contact voltage
Resistive load (cos φ ≈ 1)
Au-clad double layer contact
30V DC
0.1A
5V DC
1mA Low-level circuit rating
Item
Specifications
Expected life
Mechanical (OT) Max.
Min. 5 × 10
5
(at 60 cpm)
Electrical (Rated load OT Max.)
Min. 2 × 10
5
(at 20 cpm)
Insulation resistance
Min. 100MΩ
Dielectric strength
Between non-continuous terminals
1,000 Vrms for 1 min.
Between each terminal and other
exposed metal parts
1,500 Vrms for 1 min.
Between each terminal and ground
1,500 Vrms for 1 min.
Contact resistance (initial)
100mΩ max. (by voltage drop 0.1A 6 to 8 VDC)
Value includes the resistance between the connector and the lead (#AWG28, length: 50 mm)
Viblation resistance (malfunction vibration resistance)
10 to 55 Hz at single amplitude of 0.75mm (Contact opening: max. 1msec.)
Shock resistance (malfunction shock resistance)
Applied shock 1.50N type: Min.300m/s
2
(Contact opening: Max. 1msec.)
0.50N type: Min.150m/s
2
(Contact opening: Max. 1msec.)
Connector insertion force
Max. 20N (inserted in removal direction)
Connector holding force
Min. 20N (extracted by static load, in removal direction)
Connector removal operating times
Max. 5 times (in removal direction)
Allowable operating speed (No load)
0.1 to 1,000 mm/s (at pin plunger)
Max. operating cycle rate (No load)
300 cpm
Ambient temperature
–25 to +85°C (No freezing and condensing)
Unit weight
Approx. 2.5g (pin plunger type)
Contact specifications
Contact material
CuNi alloy + Au-clad
Protection grade
IP40
1) Lever position: Standard
Actuator
Operating Force (OF)
Max.
Release Force (RF)
Min.
Pretravel (PT)
Max.
Movement Differential
(MD) Max.
Overtravel (OT)
Min.
Operating Position
(OP)
Pin plunger
0.50N
0.04N
0.6mm
0.1mm
0.4mm
8.4±0.3mm
1.50N
0.25N
Hinge lever
0.20N
0.02N
2.6mm
0.8mm
1.2mm
10.0±0.8mm
0.50N
0.06N
Simulated roller lever
0.20N
0.02N
2.6mm
0.8mm
1.2mm
12.2±0.8mm
0.50N
0.06N
Roller lever
0.20N
0.02N
2.6mm
0.8mm
1.2mm
15.7±0.8mm
0.50N
0.06N
Downloaded from