AV6 (CS) Subminiature Switches

 5 

Panasonic Corporation Electromechanical Control Business Division

industrial.panasonic.com/ac/e/

© Panasonic Corporation 2019

AECTB60E  201903

CAUTIONS FOR USE

■ Fastening of the switch body

1) To secure the switch, please use an

M2.3 screw on a flat surface and tighten

using a maximum torque of 0.29 N·m. It

is recommended that both flat metal

washer and spring washers be used with

the screws and adhesive be applied to

lock the screws to prevent loosening of

the screws.

2) Be sure to maintain adequate

insulating clearance between each

terminal and ground.

3) When the operation object is in the

free position, force should not be applied

directly to the actuator or pin plunger.

Also force should be applied to the pin

plunger from vertical direction to the

switch.

4) In setting the movement after

operation, the over-travel should be set

more than 70% as a standard.

With the lever type, do not apply

excessive force in the direction opposite

to the movement, or from the horizontal

direction.

■ About the connector

1) The connector on the AV6 (CS) switch

is designed to fit with the XA connector

produced by JST Mfg. Co., Ltd. Do not

use any connector other than the

specified connector, or solder the

terminals directly.

2) Make sure leads are arranged so that

no constant force is applied to them when

the connectors are mated.

3) Keep the connector straight when

inserting it. If it is inserted at an angle, it

may snag near the entrance, or it may be

inserted too forcefully.

4) Problems thought to be caused by the

XA connector, which is specified as

conforming to the AV6 (CS) switch

connector, are not covered by the

warranty. Please contact JST Mfg., Co.,

Ltd. and request cooperation in resolving

the problem.

■ Selection of switch

Please make your selection so that there

will be no problems even if the operating

characteristics vary up to ±20% from the

standard values.

■ Environment

Avoid using and storing these switches in

a location where they will be exposed to

corrosive gases, silicon, or high dust

levels, all of which can have an adverse

effect on the contacts.

■ Precautions concerning circuits

The AV6 (CS) switch is designed

specifically for low-voltage, low-current

loads. Avoid using it at loads that exceed

the rating load.

■ Quality check under actual loading

conditions

To assure reliability, check the switch

under actual loading conditions. Avoid

any situation that may adversely affect

switching performance.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Содержание AV6 Series

Страница 1: ...Copying machine Printer Also for all types of equipment required for maintenance and inspections 2 SPST NO LEVER POSITION 1 Standard 2 Backward CURRENT CAPACITY reference APPLICABLE CONNECTOR Easy assembling as this switch is connector integrated Applicable connector XA connector produced by JST Mfg Co Ltd Contact SXA 001T P0 6 Housing XAP 02V 1 Connector Applicable range 100mA 1mA 0 30V 5V DC AV ...

Страница 2: ...ts 1 500 Vrms for 1 min Between each terminal and ground 1 500 Vrms for 1 min Contact resistance initial 100mΩ max by voltage drop 0 1A 6 to 8 VDC Value includes the resistance between the connector and the lead AWG28 length 50 mm Viblation resistance malfunction vibration resistance 10 to 55 Hz at single amplitude of 0 75mm Contact opening max 1msec Shock resistance malfunction shock resistance A...

Страница 3: ...7 6 3 85 7 2 5 9 5 0 08 29 2 2 4 0 05 0 1 2 4 0 05 0 1 7 7 Pin plunger type PT 0 6 Max Pin plunger type OP 8 4 0 3 10 0 Pretravel PT Max 0 6mm Movement Differential MD Max 0 1mm Overtravel OT Min 0 4mm Operating Position OP Distance from mounting hole 8 4 0 3mm CAD Data Hinge lever External dimensions 12 9 4 0 7 2 5 OP 10 0 0 08 PT 2 6 Max 2 5 0 1 5 7 9 5 0 08 29 2 2 4 0 05 0 1 2 4 0 05 0 1 7 7 10...

Страница 4: ...ever position Standard Pretravel PT Max 2 6mm Movement Differential MD Max 0 8mm Overtravel OT Min 1 2mm Operating Position OP Distance from mounting hole 12 2 0 8mm Pretravel PT Max 1 4mm Movement Differential MD Max 0 6mm Overtravel OT Min 0 7mm Operating Position OP Distance from mounting hole 11 3 0 6mm Pretravel PT Max 2 6mm Movement Differential MD Max 0 8mm Overtravel OT Min 1 2mm Operating...

Страница 5: ...than the specified connector or solder the terminals directly 2 Make sure leads are arranged so that no constant force is applied to them when the connectors are mated 3 Keep the connector straight when inserting it If it is inserted at an angle it may snag near the entrance or it may be inserted too forcefully 4 Problems thought to be caused by the XA connector which is specified as conforming to...

Страница 6: ...d The life test is performed at a switching frequency of 20 times minute and operating speed of 100 mm second at the regular cam Contact form This refers to the components determining the type of application which make up the electrical input output circuits in the contact Insulation resistance Resistance between non continuous terminals each terminal and other exposed metal parts and between each...

Страница 7: ...orce be maintained to ensure high reliability For a normally closed NC circuit the driving mechanism should be set so that the actuator is normally in the free position For a normally open NO circuit the actuator should be pressed to 70 to 100 of the specified stroke to absorb possible errors If the stroke is set too close to the operating point OP this may cause unstable contact and in the worst ...

Страница 8: ...ct resistance across COM and NO terminals is measured in the total travel position 7 To prevent contact welding failure be sure to use a serial resistance for each capacitive load 8 If snap action switch operation is synchronized with the AC supply phase this may cause shortened electrical life contact fusion failure contact transfer or other reliability problems Small current and voltage applicat...

Страница 9: ... the section CAUTIONS FOR USE for each product Avoid using in a silicon atmosphere Avoid using organic silicon rubber adhesives sealing compounds oil grease and wires in a silicon atmosphere Please consult us when using under the following conditions 1 Environments where hydrogen sulfide or other corrosive gases are present 2 Environments where gasoline thinner or other flammable explosive gases a...

Страница 10: ...ods of time Storage for extended periods of time including transportation periods at high temperatures or high humidity levels or in atmospheres with organic gases or sulfide gases may cause a sulfide film or oxide film to form on the surfaces of the contacts and or it may interfere with the functions Check out the atmosphere in which the units are to be stored and transported In terms of the pack...

Страница 11: ...ing unit Simulated roller lever Large Medium Small Possible Tip of hinge lever is bent into a semi circle enabling use as a simple roller type Leaf lever Large Large Small Excellent Play in lever is used to assure maximum stroke Construction provides for space where lever is attached for outstanding resistance to freezing Hinge roller lever Large Medium Small Possible This is a hinge lever with a ...

Страница 12: ...rrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com ...

Отзывы: