9 – 84
Aquarea air/water heat pump – Installation manual for monobloc and split systems C, D and E series 05 / 2014
Commissioning
Programming
Special functions | Reset to factory settings
➤
Press the three marked operating buttons simultaneously for
5 seconds to reset to the factory settings .
SET
SELECT
SETTING
OFF/ON
WATER OUTLET
TIMER
OUTDOOR
ACTUAL
HEATER
SETTING
STATUS
SERVICE
DEFROST
HEAT
COOL
TANK
QUIET
HEATER
FORCE
BOOSTER
STATUS
SEARCH
CANCEL
CLOCK
FORCE SERVICE
ERROR
RESET
OFF/ON
QUIET
HEATER
MODE
CHECK
TIMER
OPERATION
SET
SELECT
SETTING
STATUS
SEARCH
CANCEL
CLOCK
FORCE
ERROR
RESET
PUMPDW
OFF/ON
QUIET
HEATER
MODE
CHECK
TIMER
SET
SELECT
SETTING
STATUS
SEARCH
CANCEL
CLOCK
FORCE
ERROR
RESET
PUMPDW
OFF/ON
QUIET
HEATER
MODE
CHECK
TIMER
Reset to factory settings
Note
All settings are preserved in the
event of a power failure (stored
in EPROM) . The weekday and
time are buffered by a battery
for roughly 36 hours, after
which they must be set again .
DEFROST
SETTING
STATUS
SERVICE
7. Duration of heating period (30 min
to 10 hours, Standard: 3 hours) .
Setting the duration for heating mode
in the heating and water heating
operating mode .
DEFROST
SETTING
STATUS
SERVICE
8. Water heating duration (5 min to
1 hour 35 min, Standard: 30 min)
Setting the duration for water heating
in the heating and water heating
operating mode
9. Hot water immersion heating
function (YES / NO, Standard: NO)
DEFROST
SETTING
STATUS
SERVICE
10. Switch-on delay of the electric im-
mersion heater for hot water (20 min
to 1 hour 35 min , Standard: 1 hour)
Setting the delay period before the im-
mersion heating is switched on for the
hot-water tank if the tank temperature
is not reached
DEFROST
SETTING
STATUS
SERVICE
11. Sterilisation (YES / NO, Standard:
YES) Setting for sterilisation of the
hot water .
DEFROST
SETTING
STATUS
SERVICE
12. Day and time of sterilisation
(Standard: Monday 12:00 noon) Setting
day and time of the weekly sterilisation .
DEFROST
SETTING
STATUS
SERVICE
13. Sterilisation temperature
(40 to 75 ℃, Standard: 70 ℃)
Setting the temperature to be used
for sterilisation .
DEFROST
SETTING
STATUS
SERVICE
14. Sterilisation duration (5 min . to
1 hour, Standard: 10 min .) Setting
the period required to retain the tank
temperature required for sterilisation .