26
Press the MENU-UP button or MENU-DOWN
button to move the cursor to the NO position,
and press the SET button.
The menu protection is now released.
3
Set the LOCAL/MENU/REMOTE switch to the
LOCAL or REMOTE position.
The unit is set to the menu protect mode.
When the LOCAL/MENU/REMOTE switch is set
to the MENU position, the menu setting mode is
not established, and “MENU PROTECTED”
appears on the video monitor screen.
<Note>
If the LOCAL/MENU/REMOTE switch is set to
the MENU position while holding down the
COUNTER button on the front panel, the menu
setting mode will be established and the regular
menu settings can be performed even in the
menu protect mode.
Perform steps
2
through
7
of “Setting method
using on-screen menus.” (See page 23)
5
Setup (Initial Settings)
Set the LOCAL/MENU/REMOTE switch to the
MENU position while holding down the
COUNTER button on the front panel.
The unit is set to the menu setting mode, and the
menu screen appears on the video monitor.
1
2
MENU PROTECT OK?
NO
YES
Perform steps
2
and
3
of “How to protect the
menus.” and a screen for checking whether to
protect the menus appears on the video
monitor.
How to display the DIAG menu
Set the LOCAL/MENU/REMOTE switch to the
MENU position while holding down the EJECT
button.
The unit is set to the diagnosis display mode, and
“HOURS METER” appears on the video monitor.
1
Any item with “r” can be reset when servicing is
performed.
DIAG–MENU
HOURS METER
Ser
H00
OPERATION
00000H
H01
DRUM RUN
00000H
H02
TAPE RUN
00000H
H03
THREADING
00000T
H11
DRUM RUN r
00000H
H12
TAPE RUN r
00000H
H13
THREADING r
00000T
While the hour meters are displayed, press
the MENU-UP button or MENU-DOWN button
while holding down the PAGE button.
The deck’s serial number and software version
are displayed on the video monitor.
2
When the MENU-UP button or MENU-DOWN
button is pressed again while holding down the
PAGE button, operation returns to the hour meter
display.
DIAG–MENU
VERSION
<NTSC>
FRONT
1.
-
IF
1.
-
- .
AV-SYSCON
1.
-
- .
DV
1.
-
- .
CYLINDER
1.
-
- .
REEL
1.
-
- .
Set the LOCAL/MENU/REMOTE switch to the
LOCAL or REMOTE position.
Operation now returns to the normal mode.
3
This unit has a function for displaying hour meters,
software version and the deck’s serial number on the
video monitor.
How to release the menu
protection
Содержание AJ-D95