2-16
3-8. Tension Confirmation
SPEC
PLAY :
59mN ± 10mN (6gf ± 1gf)
REV :
88mN ± 20mN (9gf ± 2gf)
MODE
PLAY, REV
×
1
TAPE
63 min M size blank tape
123min. L size blank tape (AJ-D200,
AJ-D210, AJ-D215)
TOOL
VFK1145 (Tension Meter)
♦
Please confirm that the calibration of Tension
Meter before measurement of tension value follow
below procedure.
<Calibration of Tension Meter>
1. Connect the 7 grams calibration weight to
DVCPRO tape. (It tape and weight are included to
VFK1145.)
2. Set the above tape to the Tension Meter as
shown in figure 3-8-1.
3. Pull up the tape as speed 33mm/sec and adjust
the Tension Meter so that the meter shows 7
grams.
♦
With tape pass direction should be the same
direction of tape transportation under the VTR,
when confirm the Tension Meter as shown in figure
3-8-1.
Figure 3-8-1
1. Play back beginning portion of the tape.
2. Insert the tension meter to between S3 post and
S4 post as shown in figure 3-8-2.
3. Confirm that the tension value is within
specification.
Figure 3-8-2
4. Place the unit in REV mode.
5. Insert the tension meter to between S4 post and
S5 post as shown in figure 3-8-3.
6. Confirm that the tension value is within
specification. (Read the meter display from rear
side as shown in figure 3-8-3.)
7. If it out of specification, please perform the
Tension Arm Adjustment.
Figure 3-8-3
NOTE :
Be careful not to give some tape damage.
Содержание AJ-D400
Страница 17: ...2 1 1 Name of Tape Transportation ...
Страница 103: ...3 27 2 3 SERVO P C Board Type C D Model ...
Страница 104: ...Printed in Japan F20009912NMH ...