● In the moving average, obtain output (moving average value) from the following input.
Input: The number of average times, analog input data for the number of average times, the
latest analog input data, and old analog input data
Output: Moving average value
■
Processing during moving average
Average processing example: "Moving average" is set to 15 for the number of average times.
Analog signal
a
b
c d
e
f
g
h
i
j
k
l
m
n
o p q
r
Analog input
processing
Analog input
data
Average of a to o
Average of b to p
Average of c to q
・・・
・・・
・・・
■
Analog_8IN parameters
Name
Default
Description
Averaging process
Not execute
Select "Moving average".
Average constant
200
Specify the number of averaging times.
Count: 2 to 2,000 [times]
5.2 Average Processing Settings
WUME-GM1AIO-01
5-7
Содержание AGM1AD8
Страница 2: ... MEMO 2 WUME GM1AIO 01 ...
Страница 4: ... MEMO iv WUME GM1AIO 01 ...
Страница 8: ... MEMO viii WUME GM1AIO 01 ...
Страница 12: ... MEMO 1 4 WUME GM1AIO 01 ...
Страница 18: ... MEMO 2 6 WUME GM1AIO 01 ...
Страница 26: ... MEMO 3 8 WUME GM1AIO 01 ...
Страница 38: ... MEMO 4 12 WUME GM1AIO 01 ...
Страница 54: ...REFERENCE 4 2 Setting Parameters and Performing I O Mapping 5 6 Max Min Hold Function 5 16 WUME GM1AIO 01 ...
Страница 58: ... MEMO 5 20 WUME GM1AIO 01 ...
Страница 68: ... MEMO 6 10 WUME GM1AIO 01 ...
Страница 79: ...Digital input value Analog output value 640 or less Output at 0 9 V 8 1 Voltage Range WUME GM1AIO 01 8 5 ...
Страница 84: ... MEMO 9 4 WUME GM1AIO 01 ...
Страница 94: ... MEMO App 4 WUME GM1AIO 01 ...
Страница 95: ...Record of Changes Date Manual No Record of changes August 2021 WUME GM1AIO 01 1st edition WUME GM1AIO 01 ...
Страница 96: ... MEMO WUME GM1AIO 01 ...
Страница 97: ... MEMO WUME GM1AIO 01 ...
Страница 98: ...Panasonic Corporation 2021 August 2021 WUME GM1AIO 01 ...