90
RS-232C
$
Query control commands
Data transmitted by PC
Data returned from unit in response
Description of command
[STX] QMS [ETX]
[STX] LMSm [ETX]
Parameter
m = 0: 1 second
1: 1.5 seconds
2: 2 seconds
3: 2.5 seconds
4: 3 seconds
5: 4 seconds
6: 5 seconds
7: 10 seconds
Queries the timing at which to switch the video signals
which are supplied from the camera and which are to be
output from the rear panel VIDEO OUT connector.
[STX] QLD:n [ETX]
Parameter
n = 0—7
Up to the last 8 sets of data are
designated by this parameter with 0
serving as the latest data.
[STX] LANnn:data1:data2 [ETX]
Parameter
nn = 00—99: Alarm number
data1 = yyyymmdd
yyyy = 2000—2099: Gregorian
calendar
mm:
01—12: Month
dd =
01—31: Day
data2 = hhmmss
hh = 00—23: Hours (24-hour system)
mm = 00—59: Minutes
ss =
00—59: Seconds
Queries the ALARM RECALL data.
[STX] QLE [ETX]
[STX] LRIm [ETX]
Parameter
m = A: Alarm signal input is
acknowledged.
F: Alarm signal input is ignored.
Queries the setting for the alarm recording and/or sensor
recording to be performed if an alarm signal has been input
while repeat recording is underway or while the tape is
being rewound.
[STX] QLH [ETX]
[STX] LHRhhhh [ETX]
Parameter
hhhh = 0000—9999
The cumulative drum rotation time in
hours is returned as a 4-digit figure.
Queries the current value of the hour meter.
[STX] QLM [ETX]
[STX] LRMm [ETX]
Parameter
m = E: External timer recording
I:
Internal timer recording
N: Regular recording
Queries the timer recording mode setting.