24
Useful functions
Alarm recording and sensor
(emergency) recording
Alarm recording
This function enables recording with changes made to
the time mode and/or cameras used for recording
when an alarm signal (see page 35 for details on the
alarm recording connections) is input during
recording.
Sensor (emergency) recording
This function enables recording with changes made to
the time mode and/or cameras used for recording as
soon as an alarm signal is input even when the unit’s
power is off.
1
Set the POWER switch to ON, and insert the
cassette tape.
2
Set the PROGRAM switch to the MENU position.
The setting menu screen now appears on the TV
monitor.
3
Press the PAGE (+) or PAGE (–) button to display
the P4 ALARM/SENSOR REC screen.
The flashing items are ones that can be set.
4
Take the following steps to set the recording mode
to be established when an alarm signal is input:
O
Use the (
4
) and (
3
) SHIFT buttons to move the
flashing part to the item whose setting is to be
changed.
O
Press the (+) and (–) SET buttons, and change
the setting.
<Notes>
O
Alarm recording and sensor recording are
selected using the MODE item.
Select OFF as the MODE item setting if
recording is not to be performed when an alarm
signal is input.
O
The recording time (DURATION) is set as
follows between 30 seconds and 10 minutes:
CONTINUE (up to the tape-end) or MANUAL
(while the alarm signal is input).
5
When the settings are completed, set the
PROGRAM switch to the OFF position.
The setting menu screen is cleared from the TV
monitor, and the normal mode is restored.
<
2
1
2
1
6
5
∫
;
3
4
3
4
3
4
H
H
1
2•5
3
4
ALARM
[RECORDING MODE]
P4
FIELD/FRAME
FIELD
PICTURE QUALITY
HIGH
REC-TYPE
RT0 ( OFF
¢
16)
[ALARM/SENSOR REC]
MODE
OFF
FIELD/FRAME
FIELD
PICTURE QUALITY
HIGH
DURATION
0.5min
BUZZER
OFF
REPEAT
OFF
GROUP ALARM1
RT0 ( OFF
¢
16)
GROUP ALARM2
RT0 ( OFF
¢
16)