3.3.3 Averaging Processing Setting
When an averaging processing setting is entered, the analog average count is set.
■
Applicable model
Model
Channel
AFPXHEAD4
CH0 to CH3
AFPXHEAD8
CH0 to CH7
AFPXHEA21
CH0 to CH1
■
Averaging processing setting
H1: Moving average 10 times (Maximum and minimum values are deleted.)
H2: No. of averaging times: 64 times
H3: No. of averaging times: 128 times
H0, H4 to F: Do not use the averaging processing.
■
I/O allocation
Channel
Expansion location
1st unit
2nd unit
3rd unit
4th unit
5th unit
6th unit
7th unit
8th unit
Averaging
processing setting 1
CH0 to CH3
WY32
WY42
WY52
WY62
WY72
WY82
WY92
WY102
Averaging
processing setting 2
CH4 to CH7
WY33
WY43
WY53
WY63
WY73
WY83
WY93
WY103
■
I/O contents
Averaging processing setting 1
The range setting data for each channel data is allocated from the lower level in the order of
CH0, CH1, CH2, and CH3.
Averaging processing setting 2
The range setting data for each channel data is allocated from the lower level in the order of
CH4, CH5, CH6, and CH7.
3.3 Stored Data of the Output Contact (WY)
3-10
WUME-FPXHAIO-01
Содержание AFPXHEAD4
Страница 2: ...MEMO 2 WUME FPXHAIO 01...
Страница 5: ...Indicates operation procedures WUME FPXHAIO 01 v...
Страница 6: ...MEMO vi WUME FPXHAIO 01...
Страница 26: ...MEMO 2 10 WUME FPXHAIO 01...
Страница 42: ...3 4 Analog Input Functions 3 16 WUME FPXHAIO 01...
Страница 46: ...3 5 Analog Output Functions 3 20 WUME FPXHAIO 01...
Страница 56: ...MEMO 4 10 WUME FPXHAIO 01...
Страница 62: ...MEMO 5 6 WUME FPXHAIO 01...
Страница 72: ...MEMO 7 6 WUME FPXHAIO 01...
Страница 75: ...MEMO WUME FPXHAIO 01...