30
Model C-ET Installation Guide
1.3.4.4
Installing the First Mounting Block (cont.)
4.
Tighten the chain around the pipe so the mounting block can be moved for adjustments.
5.
Insert the C-ET transducer without couplant into the mounting block. Confirm that the C-ET mounts into the slider
properly.
6.
Use the pressure bolt to secure the C-ET transducer. Hand-tighten enough to hold the C-ET transducer in place.
Do not overtighten so that the holder lifts off the pipe.
7.
Adjust the mounting block so the center of the waveguide lines up with the origin line on the pipe. Also, make sure
the front edge of the mounting block is still lined up with the circumferential line. When the mounting block is
properly aligned, tighten the chain to secure it.
Pressure Bolt
Circumference Line
Origin Scribe Line
Holder