Model C-ET Installation Guide
23
1.3.3.5
Mounting the Transducers (cont.)
5.
Insert the transducers into the mounting blocks, making sure the BNC connectors (or junction boxes) point away
from the center of the fixture. Tighten the pressure bolts to hold the transducers in place. Hand tighten the bolt
enough so the transducer makes contact with the pipe.
6.
Measured soundspeed should be within 0.25% of the programmed value. Reprogram the measured value into
the flowmeter and change the sensor spacing as calculated if the difference is greater than 0.25%. Replace the
RTV couplant every time the sensor spacing is changed. Repeat the procedure (steps 5 and 6), if necessary, until
the soundspeeds are within 0.25%.
7.
Remove the CPL-16 and prepare the transducer for solid couplant.
Содержание C-ET