
BWT™ System Installation Guide
11
Chapter 2. Standard Installation (FTPA Buffers)
2.3 Assembling the Standard FTPA Buffer
Note:
If the BWT system is shipped with the buffers already installed in the nozzles, proceed to “Installing the BWT
.
1.
Slide the lap-joint flange over the threaded end of the FTPA Buffer. Make sure you orient the flange as shown
below.
2.
Check the raised face of the spool nozzle flange to make sure it is free from paint, rust, dirt, corrosion, and
damage. If necessary, clean the raised faces with steel wool. In addition, clean the buffer flange if you are reusing
an existing buffer.
3.
Inspect the gaskets supplied by Panametrics. They must not be used, warped, pitted or scratched.
4.
Place one gasket on the end of the buffer assembly.
Lap-Joint Flange
Side View
FTPA Buffer
Raised Edge
Side View
Coupler Raised Face
Gasket
Side View
Содержание BWT System
Страница 1: ...panametrics com Flow 916 058 F July 2021 BWT System Installation Guide ...
Страница 2: ......
Страница 4: ...ii no content intended for this page ...
Страница 8: ...Contents BWT System Installation Guide ...
Страница 16: ...Chapter 1 General Information 8 BWT System Installation Guide no content intended for this page ...
Страница 52: ...Chapter 5 Specifications 44 BWT System Installation Guide no content intended for this page ...
Страница 54: ...46 BWT System Installation Guide no content intended for this page ...
Страница 57: ......