● In Link Mode :
○ An audit trail remains.
○ A real-time alert will be sent to the Owner’s and Family’s app.
Lock Out
● When locking out, the keypad panel is out of function and the Led keeps flashing
slowly every 5 seconds. No the other functions to the lock will be affected.
● A lockout will be removed when successfully access the lock by any method.
● Three-stage of the lockout:
○ Stage 1: Three failed attempts lead to 3 minutes lockout.
○ Stage 2: Continuously, another three failed attempts lead to 30 minutes
lockout.
○ Stage 3: Continuously, another three failed attempts will lockout permanently.
Only the lock access by another method will enable the keypad.
● In Stand-Alone Mode :
○ All the lockout stages are recorded in the audit trail.
● In Link Mode :
○ All the lockout stages are recorded in the audit trail.
○ A real-time alert will be sent to the Owner’s and Family’s app in every lockout
stage.
Volume Control
● There are three stages of volume control. Mute is available. Default is the medium.
● Use the Keypad Command to set the volume when In Keypad Programming Mode.
● Stand-Alone Mode and LINK Mode.
○ Make sure the app can connect the lock via the Bluetooth.
○ An audit trail remains when the volume changes.
Auto-Lock
● Auto-lock can be off. The factory default is on and delays 10 seconds
● The delay can be 10~99 seconds.
● Use the Keypad Command to set the volume when In Keypad Programming Mode.
● Stand-Alone Mode and LINK Mode.
○ Make sure the app can connect the lock via the Bluetooth.
● Stand-Alone Mode :
○ An audit trail remains
● LINK Mode :
○ An audit trail remains
Lock Error
● Lock error situations
8