background image

16

MISO FIREBOWL | Owner and Installation Manual

WARRANTY INFORMATION

KEEP THIS FOR WARRANTY

MODEL: (circle one) 

CIR-18

 

 

 

CIR-18P

   

SERIAL NO:

DATE PURCHASED:

OUTDOOR FIRE PIT BURNER: LIMITED LIFETIME WARRANTY

The following components are warranted for life to the original owner, subject to proof of purchase: 

BURNER 18 - Outdoor Fire Pit Burner - manufactured by Hevi Manufacturing Inc for Paloform.

BASIC WARRANTY

Paloform warrants the components and materials in your appliance to be free from manufacturing and material 

defects for a period of one year from date of installation. After installation, if any of the components manufactured 

by Paloform in the appliance are found to be defective in materials or workmanship, Paloform will, at its option, 

replace or repair the defective components at no charge to the original owner. Paloform will also pay for reasonable 

labor cost incurred in replacing or repairing such components for a period of one year from date of installation. Any 

products presented for warranty repair must be accompanied by a dated proof of purchase.

This Limited Lifetime Warranty will be void if the appliance is not installed by a qualified installer in accordance 

with installation instructions. The Limited Lifetime Warranty will also be void if the appliance is not operated and 

maintained according to the operating instructions supplied with the appliance, and does not extend to (1) fire pit 

burner assembly damaged by accident, neglect, misuse, abuse, alterations, negligence of others, including the 

installation thereof by unqualified installers, (2) the costs of removal, reinstallation or transportation of defective 

parts on the appliance, or (3) incidental or consequential damage. All service work must be performed by an 

authorized service representative.

This warranty is expressly in lieu of other warranties, express or implied, including the warranty of merchantability 

of fitness for purpose and of all other obligations or liabilities. Paloform does not assume for it any other obligations 

or liabilities in connection with sale or use of the appliance. In states that do not allow limitations on how long an 

implied warranty lasts, or do not allow exclusion of indirect damage, those limitations of exclusions may not apply 

to you. You may also have additional right not covered in the Limited Lifetime Warranty. Paloform reserves the right 

to investigate any and all the claims against this Warranty and decide upon method of settlement. For information 

about this warranty contact:

Paloform

2680 Matheson Blvd

Suite 102

Mississauga ON L4W 0A5

Canada

888.823.8883

Содержание MISO CIR-18

Страница 1: ... department WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cyllinder not connected for use shall not be stored in the vicinity of this or any other appliance CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in an enc...

Страница 2: ...FPA 54 or the International Fuel Gas Code 3 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 4 Do not burn solid fuel in this appliance Do not use this appliance to cook food or to burn paper or other objects 5 Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clo...

Страница 3: ...ithin this area This will ensure that the final position of the unit will not be compromised We recommend that gas risers be kept as low to grade as possible and no higher than 6 at their highest points ATTENTION Gas line must be installed by a licensed contractor in compliance with local codes FIG 1 PLAN AND VERTICAL SECTION See page 8 of this manual for Gas Installation Requirements POSITIONING ...

Страница 4: ...l and evenly supported 7 Connect to Natural Gas or Propane Source as per page 8 of this manual 8 Assemble Burner as per instructions on page 7 9 Check for leaks and test burner see page 8 10 Remove Control Knob 4 and stem from valve assembly Align valve with Control Knob hole Place Burner Assembly into Body Visually check to ensure that the valve is aligned with the hole 11 Push Control Knob 4 bac...

Страница 5: ...5 MISO FIREBOWL Owner and Installation Manual 1 Burner Assembly 6 Flex Hose Gas Connection 5 Topping Ring 2 Valve Assembly 4 Control Knob 3 Body FIG 2 Miso Firebowl Exploded COMPONENTS ...

Страница 6: ...6 MISO FIREBOWL Owner and Installation Manual FIG 3 MINIMUM CLEARANCES TO COMBUSTIBLES CLEARANCE TO COMBUSTIBLES 72 72 12 16 MISO SOBA ...

Страница 7: ... BURNER 1 Connect the Burner Assembly to the gas propane supply using the supplied flex connector and following the instructions on page 8 2 Carefully leak test all connections following the procedure on page 8 3 Fill the burner pan evenly with burner media crushed glass for NG lava rock for LP fully covering burner ring Media should be level with the top rim of the pan Do not obstruct lighting po...

Страница 8: ...ame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test Pressures in Excess Of 1 2 psi 3 5 kPa This appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ...

Страница 9: ...Specifications Minimum Clearances to Combustible Materials MODEL MAX INPUT Btu Hr INLET PRESSURE MIN INLET PRESSURE MAX MANIFOLD PRESSURE ORIFICE SIZE BURNER PORTS PORT SIZE CIR 18 69 000 4 5 W C 10 5 W C 3 5 W C 18 68 1 8 CIR 18P 60 000 11 0 W C 13 0 W C 10 0 W C 37 68 1 8 ABOVE SIDE BELOW 72 18 0 ...

Страница 10: ...e can result in injury or property damage For assistance or additional information consult a qualified installer service agency or the gas supplier Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this appliance INITIAL LIGHTING INSTRUCTIONS 1 Purge air from the supply line as follows Open the main shutoff valve Unscrew the main pressure test point Leave the inl...

Страница 11: ... gas control knob and light the pilot immediately by applying a flame to the lighting port Hold the knob down for one full minute after lighting the pilot 4 When the gas control knob is released the pilot flame should continue to burn if the pilot goes out repeat the above steps 5 Rotate the gas control knob from PILOT to ON position full counterclockwise position to supply full flow to main burne...

Страница 12: ...e the burner porting and burner air openings are free of obstructions at all times Inspect area around the burner Remove any lint or foreign material with a brush or vacuum cleaner The burner must be replaced prior to the appliance being put into operation if it evident that the burner is damaged PILOT FLAME The flames from the pilot should be visually checked as soon as the unit is installed and ...

Страница 13: ...arning statement below 1 Locate and correct all leaks see Checking Gas Connections pg 5 Pilot cannot be lit 1 Gas supply turned off or manual shutoff valve closed 2 Air in gas lines when installed 3 Pilot adjustment screw closed 4 Pilot is clogged 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Adjust pilot flame for approximately 1 blue flame 4 Clean pilot se...

Страница 14: ...T x 1 2 MFL Connector 3 8 MPT x 1 2 MFL Connector 3 8 Nipple Close 1 2 Flex Connector 10 1 1 1 1 1 1 2 1 2 RBP018 PAN025 VNG017 O33018 LN111C CO488C CO468C CO112C FC4810 RBP018 PAN025 VLP017 O33037 LN111C CO488C CO468C CO112C FC4810 KEY DESCRIPTION QTY CIR 18 CIR 18P 10 10b 11 12 13 14 15 16 Main Valve Control Knob Pilot Assembly Pilot Shield Regulator Valve Bracket Set 2 pieces Burner Media Glass...

Страница 15: ...15 MISO FIREBOWL Owner and Installation Manual 10 11 12 6 8 3 5 13 14 4 9 15 16 ILLUSTRATED PARTS LIST cont d ...

Страница 16: ...llation instructions The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 fire pit burner assembly damaged by accident neglect misuse abuse alterations negligence of others including the installation thereof by unqualified installers 2 the costs of removal reinsta...

Отзывы: