Paloform MISO CIR-18 Скачать руководство пользователя страница 2

2

MISO FIREBOWL | Owner and Installation Manual

SAFETY INFORMATION

 WARNINGS:

IMPORTANT: This appliance should 

be inspected before use and at 

least once annually by a qualified 

service person.

More frequent cleaning may 

be required as necessary. It 

is imperative that the control 

compartment, burners and 

circulating air passageways of the 

appliance be kept clean.

DANGER: Carbon monoxide 

poisoning can lead to death!

CARBON MONOXIDE POISONING:

Early signs of carbon monoxide 

poisoning resemble the flu, with 

symptoms including headache, dizziness, 

or nausea. If you experience these signs, 

the Fire Pit may not be working properly. 

Get fresh air at once! Have the Fire Pit 

serviced. Some people are more affected 

by carbon monoxide than others, 

including pregnant women, people with 

heart or lung disease or anemia, those 

under the influence of alcohol, and those 

at high altitudes.

NATURAL GAS AND PROPANE: 

To assist in detecting leaks, an odorant 

has been added to natural gas and 

propane. However, this odorant can fade, 

and gas may be present even though no 

odor exists. Make certain you read and 

understand all warnings. Keep this manual 

for reference. It is your guide to safe and 

proper operation of this appliance.

WARNING:

 Any modification to this appliance or its 

controls can be dangerous.

1.  This appliance, as supplied, is only for use with the 

type of gas indicated on the rating plate.

2.  When this appliance is connected to a fixed piping 

system, the installation must conform to local codes, 

or in the absence of local codes, to the National 

Fuel Gas Code, ANSI Z223.1/NFPA 54, or the 

International Fuel Gas Code.

3.  Keep the appliance area clear and free from 

combustible materials, gasoline and other flammable 

vapors and liquids

4.  Do not burn solid fuel in this appliance. Do not use 

this appliance to cook food or to burn paper or other 

objects.

5.  Children and adults should be alerted to the 

hazards of high surface temperatures and should 

stay away to avoid burns or clothing ignition.

6.  Clothing or other flammable materials should not 

be hung from the appliance, or placed on or near 

the appliance.

7.  Young children should be carefully supervised 

when they are in the area of the appliance.

8.  Do not use the appliance if any part has been under 

water. Immediately call a qualified service technician 

to inspect the appliance and to replace any part of 

the control system and any gas control which has 

been under water.

9.  Inspect the appliance before each use.

10. Turn the appliance off and let cool before servicing, 

installing, repairing or covering. Any guard or other 

protective device removed for servicing the 

appliance must be replaced prior to operating the 

appliance. Only a qualified service person should 

install, service, or repair the appliance.

HIGH ALTITUDE INSTALLATION

The appliance is rated for installations up to 4500’ (1372 

m) above sea level. Above 4500’ the appliance must be 

derated at the factory for the appropriate altitude unless 

the local fuel is pre derated.

LOCAL CODES

Install and use your Outdoor Fire Pit with care. Follow 

local codes. In the absence of local codes, use the latest 

edition of The National Fuel Gas Code ANSI Z223.1/

NFPA 54 available from:

American National Standards Institute Inc.

1430 Broadway

New York NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy MA 02269.

Содержание MISO CIR-18

Страница 1: ... department WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cyllinder not connected for use shall not be stored in the vicinity of this or any other appliance CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in an enc...

Страница 2: ...FPA 54 or the International Fuel Gas Code 3 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 4 Do not burn solid fuel in this appliance Do not use this appliance to cook food or to burn paper or other objects 5 Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clo...

Страница 3: ...ithin this area This will ensure that the final position of the unit will not be compromised We recommend that gas risers be kept as low to grade as possible and no higher than 6 at their highest points ATTENTION Gas line must be installed by a licensed contractor in compliance with local codes FIG 1 PLAN AND VERTICAL SECTION See page 8 of this manual for Gas Installation Requirements POSITIONING ...

Страница 4: ...l and evenly supported 7 Connect to Natural Gas or Propane Source as per page 8 of this manual 8 Assemble Burner as per instructions on page 7 9 Check for leaks and test burner see page 8 10 Remove Control Knob 4 and stem from valve assembly Align valve with Control Knob hole Place Burner Assembly into Body Visually check to ensure that the valve is aligned with the hole 11 Push Control Knob 4 bac...

Страница 5: ...5 MISO FIREBOWL Owner and Installation Manual 1 Burner Assembly 6 Flex Hose Gas Connection 5 Topping Ring 2 Valve Assembly 4 Control Knob 3 Body FIG 2 Miso Firebowl Exploded COMPONENTS ...

Страница 6: ...6 MISO FIREBOWL Owner and Installation Manual FIG 3 MINIMUM CLEARANCES TO COMBUSTIBLES CLEARANCE TO COMBUSTIBLES 72 72 12 16 MISO SOBA ...

Страница 7: ... BURNER 1 Connect the Burner Assembly to the gas propane supply using the supplied flex connector and following the instructions on page 8 2 Carefully leak test all connections following the procedure on page 8 3 Fill the burner pan evenly with burner media crushed glass for NG lava rock for LP fully covering burner ring Media should be level with the top rim of the pan Do not obstruct lighting po...

Страница 8: ...ame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test Pressures in Excess Of 1 2 psi 3 5 kPa This appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ...

Страница 9: ...Specifications Minimum Clearances to Combustible Materials MODEL MAX INPUT Btu Hr INLET PRESSURE MIN INLET PRESSURE MAX MANIFOLD PRESSURE ORIFICE SIZE BURNER PORTS PORT SIZE CIR 18 69 000 4 5 W C 10 5 W C 3 5 W C 18 68 1 8 CIR 18P 60 000 11 0 W C 13 0 W C 10 0 W C 37 68 1 8 ABOVE SIDE BELOW 72 18 0 ...

Страница 10: ...e can result in injury or property damage For assistance or additional information consult a qualified installer service agency or the gas supplier Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this appliance INITIAL LIGHTING INSTRUCTIONS 1 Purge air from the supply line as follows Open the main shutoff valve Unscrew the main pressure test point Leave the inl...

Страница 11: ... gas control knob and light the pilot immediately by applying a flame to the lighting port Hold the knob down for one full minute after lighting the pilot 4 When the gas control knob is released the pilot flame should continue to burn if the pilot goes out repeat the above steps 5 Rotate the gas control knob from PILOT to ON position full counterclockwise position to supply full flow to main burne...

Страница 12: ...e the burner porting and burner air openings are free of obstructions at all times Inspect area around the burner Remove any lint or foreign material with a brush or vacuum cleaner The burner must be replaced prior to the appliance being put into operation if it evident that the burner is damaged PILOT FLAME The flames from the pilot should be visually checked as soon as the unit is installed and ...

Страница 13: ...arning statement below 1 Locate and correct all leaks see Checking Gas Connections pg 5 Pilot cannot be lit 1 Gas supply turned off or manual shutoff valve closed 2 Air in gas lines when installed 3 Pilot adjustment screw closed 4 Pilot is clogged 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Adjust pilot flame for approximately 1 blue flame 4 Clean pilot se...

Страница 14: ...T x 1 2 MFL Connector 3 8 MPT x 1 2 MFL Connector 3 8 Nipple Close 1 2 Flex Connector 10 1 1 1 1 1 1 2 1 2 RBP018 PAN025 VNG017 O33018 LN111C CO488C CO468C CO112C FC4810 RBP018 PAN025 VLP017 O33037 LN111C CO488C CO468C CO112C FC4810 KEY DESCRIPTION QTY CIR 18 CIR 18P 10 10b 11 12 13 14 15 16 Main Valve Control Knob Pilot Assembly Pilot Shield Regulator Valve Bracket Set 2 pieces Burner Media Glass...

Страница 15: ...15 MISO FIREBOWL Owner and Installation Manual 10 11 12 6 8 3 5 13 14 4 9 15 16 ILLUSTRATED PARTS LIST cont d ...

Страница 16: ...llation instructions The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 fire pit burner assembly damaged by accident neglect misuse abuse alterations negligence of others including the installation thereof by unqualified installers 2 the costs of removal reinsta...