9
MISO FIREBOWL | Owner and Installation Manual
01
25"
6
"
18"
TECHNICAL DATA
Burner Dimensions
Burner Specifications
Minimum Clearances to Combustible Materials:
MODEL #
MAX INPUT
Btu/Hr
INLET
PRESSURE MIN
INLET
PRESSURE MAX
MANIFOLD
PRESSURE
ORIFICE SIZE
BURNER PORTS
PORT SIZE
CIR-18
69,000
4.5” W.C.
10.5” W.C.
3.5” W.C.
18
68
1/8”
CIR-18P
60,000
11.0” W.C.
13.0” W.C.
10.0” W.C.
37
68
1/8”
ABOVE
SIDE
BELOW
72”
18”
0”