7-Way
Plug
Liftgate
Mount Frame
2Ga Power Cable
From Liftgate (+)
Ground Cable
From Liftgate (-)
(+)
(-)
***Resetable
Circuit
Breaker
*In-Line
Fuse
Wires #2 and #4
go to postitive (+)
4-Conductor
Power Cable
from Control Board
Wires #1 and Gr/Yl
go to ground (-)
Trail Charger
Aux.
Batteries
Ground
**In-Line
Fuse
*In-Line ATC Fuse: 20 Amp.
Replace with same amperage fuse when necessary.
**
In-Line ATC Fuse: 40 Amp.
Replace with same amperage fuse when necessary.
***Resetable Circuit Breaker: 150 Amp Min.
Replace with same amperage breaker when necessary.
NOTICE: DO NOT attempt to jump in-line fuses with other objects other than the specified fuse(s).
DO NOT increase the amperage rating of fuse. Serious harm to the liftgate will result when
standard practices are not followed.
Trail Charging System