ILSL 33/44 Owner‘s Manual
Rev.1.1
28
7. Are there any damages on mechanical or electrical parts (such as damaged cables)?
Perform a visual inspection of all electrical wiring and mechanical components.
7.2
ON/OFF switch is ON but all functions are dead
Possible malfunctions:
1. Short in hand held remote or its wire, unplug hand held control at J31. Remove J1 plug for 5
seconds. Reinstall J1, try main control board switches. If gate operates the problem is in the hand
held control or its wiring.
2. Short in control box wire remove J30 plug. Remove J1 plug for 5 seconds. Reinstall J1, try hand
held remote. If gate operates the problem is in the control box swtiches or harness.
After disconnecting plugs – reboot board by unplugging J-1 for 5 seconds and plug it back.
If gate is still not working, take truck/trailer to an authorized repair station.
Содержание ILSL 33/44
Страница 1: ...ILSL 33 44 OWNERS MANUAL 11 14 ...
Страница 11: ...ILSL 33 44 Owner s Manual Rev 1 1 11 NOTES ...
Страница 21: ...ILSL 33 44 Owner s Manual Rev 1 1 21 NOTES ...