69
10.6. Checking alignment of the platform
(only PTC 750 L, LLW)
►
Move the platform horizontally to the end stop of the case and then back
again a few millimetres.
►
Position the platform parallel to the end stop using the adjusting screw on
the tilt link (see Figure 46).
Figure 46: Tilt link, PTC 750
►
Tighten the bolted connection between the underrun protection and the
tilt link.
►
Now check that the platform stops on both sides simultaneously.
►
Repeat the steps to align the platform if this is not the case.
Bolted connection
Underrun protection
Adjustment screw
Tilt link