USER PANEL
CONNECTIONS
IN
S1
Generator probe
7HPSHUDWXUH5DQJH&
FLUX/S2
'RPHVWLFZDWHUÀRZPHWHU
On/Off
Domestic water
7HPSHUDWXUH5DQJH&
OUT
P1
Generator pump probe
230 Vac
3(N) - 4(Fon)
VALV
Domestic water valve
230 Vac
5(N)-6(Foff)-7(Fon)
AUX
Auxiliary
Potential free contact
8(com)-9(nc)-10(no)
P2
System pump
230 Vac
11(n)-12(Fon)
0$18$/7&&
INSTALLATION OF A PELLET GENERATOR WITHOUT AN ON-BOARD CIRCULATOR
REMEMBER:
The hydraulic kit can also be combined with pellet generators without an on-board circulator.
In this case, depending on the type of kit selected, it is possible to proceed in two different ways:
“P” series hydro kit
If you decided to install a “P” series kit, the plumber must also prepare, in addition to the kit, a second circulator that starts with the consent of
the pellet stove (follow the instructions in the stove instruction booklet).
“L” series hydro kit
If you decided to install an “L” series kit, the electrician must disconnect
the circulator’s power supply cables on the primary branch (cables 3 and
4 in the figure) on board the hydraulic kit and connect them by means of a
mammoth, with an extension cable (not supplied), to the terminal board on
the pellet generator (follow the instructions in the stove instruction booklet).
In this way, the pellet generator will provide activation consent to the
circulator (on board the kit).
1 2 3 4 5 6 7 8 9 10 11 12
P2
P3
P4
VALV
P 1
AUX
P 2
OFF
P1
50