KIT P5: PRODUCT DESCRIPTION
500
450
1
2
3
7
8
9
10
11
12
13
14
5
40
60
60
60
60
170
100
60
160
A
B
D
E
C
1. System return tap with anti-return
¾”M x ¾”M
2. System delivery tap and domestic water coil
¾”M x 1"F
3. System circulation pump
GRUNDFOS UPM3 HYBRID
4. Generator circulation pump
/
5. Diverter valve
VZA - 1"
6. System return probe
/
7. System air vent
fast
8. Generator air vent
fast
9. Plate exchanger
40 plates
10. Generator delivery probe
17&.ȍ#
11. Control unit
TC 100
12. Generator delivery tap
¾”M x ¾”M
13. Generator return tap
¾”M x ¾”M
14. Metal box
Painted in white
A) Return from heating circuit
¾”M
B) Heating circuit/domestic water coil delivery
¾”M
C) Domestic water coil return
¾”M
D) Return to generator
¾”M
E) Delivery from generator
¾”M
&RQWUROXQLWFRQ¿JXUDWLRQ&)*
40