25
- 6.1 -
> 3,5 ÷ 4 m
ENGLISH
6 PREPARING
THE
INSTALLATION
6.1 SAFETY
PRECAUTIONS
The responsibility for any work done in the space
ZKHUH WKH ¿UHSODFH LV WR EH LQVWDOOHG LV DQG
remains, the user’s. The user is also entrusted with
carrying out the checks regarding the proposed
installation solutions.
The user must comply with all the local, national
and European rules and regulations.
,IWKHÀRRUGRHVQRWKDYHDVXI¿FLHQWORDGEHDULQJ
capacity, it is advisable to use a load-distributing
plate of an appropriate size.
7KHDSSOLDQFHPXVWEHLQVWDOOHGRQDÀRRUZLWKDQ
adequate carrying capacity.
,IWKHÀRRUGRHVQRWKDYHDVXI¿FLHQWORDGEHDULQJ
capacity, it is advisable to use a load-distributing
plate of an appropriate size.
The cooker assembly and disassembly operations
must be carried out by skilled technicians only.
It is always advisable for the user to call our
DVVLVWDQFH VHUYLFH ZKHQ WKH\ QHHG TXDOL¿HG
technicians.
If other technicians are called in, please make
VXUHWKH\DUHWUXO\TXDOL¿HG
Before starting the assembly or dismantling
phases of the machine, the installer must comply
with the safety precautions as established by law,
and in particular :
A) he must not work in adverse conditions;
B) he must be in perfect psychophysical condition
to work and ensure that the individual and
personal accident prevention devices are
sound and in perfect working order;
C) he must wear accident prevention gloves;
D) he must wear safety shoes;
E) he must make sure that the area he is working
LQIRUDVVHPEOLQJGLVPDQWOLQJWKH¿UHSODFHLV
free from obstacles.
6.2 FLUES AND CHIMNEY TOPS
7KHÀXHSLSHIRUWKHGLVFKDUJHRIVPRNHPXVWEH
compliant with standards EN 10683, EN 1856-1-
2, EN 1857, EN 1443, EN 13384-1-3, EN 12391-
1 both in terms of size and materials used to
construct it.
FLUE
dimensions must comply with the
instructions given in the technical data sheet.
Flue cross-section should be kept constant for
all its height. A minimum height of 3.5÷4 m is
recommended ( - 6.1 - ). Under the outlet of
the smoke pipe there should be a chamber for
gathering solid materials and any condensation.
A
PERFECT DRAUGHT
is above all the result
RI D ÀXH WKDW LV FOHDU RI REVWUXFWLRQV VXFK DV
chokes, horizontal sections or corners; any axial
displacements should be at a maximum angle
of 45° compared to the vertical axis, (better still
if it is only 30°). These displacements should
preferably be effected near the chimney top.
The
SMOKE
connection between the cooker
DQG ÀXH VKRXOG KDYH WKH VDPH FURVV VHFWLRQ
as the cooker
¶VVPRNHRXWOHW7KHVPRNH¿WWLQJ
PXVWEHVHDOHGDQGWKHXVHRIÀH[LEOHPHWDOOLF
pipes is prohibited. Changes in direction in
respect to the smoke outlet of the appliance
must be executed using elbows not exceeding
45° in respect to vertical.
The
CHIMNEY TOP
shall be the
WINDPROOF
type with an inside cross section equivalent to
WKDWRIWKHÀXHDQGZLWKDVPRNHRXWOHWSDVVDJH
section at least
DOUBLE
the internal one of the
ÀXH
To avoid draught problems, each cooker should
KDYHLWVRZQÀXH,IWKHUHLVPRUHWKDQRQHÀXH
on the roof the others should be situated at a
distance of at least 2 metres and the cooker ’s
chimney top should be at least 40 cm
ABOVE
the others. If the chimney tops are near each
other install some dividing panels.
If
the
cooker
LVLQVWDOOHGZLWKDÀXHWKDWKDVDOUHDG\
been used it should be cleaned thoroughly to avoid
malfunctions and the danger of unburned parts
GHSRVLWHGRQWKHLQVLGHIURPFDWFKLQJ¿UH8QGHU
QRUPDOFRQGLWLRQVRIXVHRIWKHVWRYHWKHÀXHVKRXOG
be cleaned at least once a year.
Содержание ALBA 3.5