Model: 

ZENIT 18m „L” 

Gas-fired overhead radiant tube heaters Linear shape

Type of heating: Radiant tube

Fuel:  Gaseous

Type of fuel: Natural Gas

Propane

Butane

Propane-Butane

Space heating emission NOx

152.9

mg/kWh

input

 (GCV)

Characteristics when operating with the preferred fuel only

Item 

Symbol  Value 

Unit 

Item 

Symbol  Value 

Unit 

Heat output

 Useful efficiency - GCV

Nominal 

heat output

P

nom

55.3

kW

Useful efficiency at nominal 

heat output 

h

th.nom

83.34

%

Minimum 

heat output 

P

min

38.4

kW

Useful efficiency at minimum 

heat output 

h

th.min

81.60

%

Minimum heat 

output -

 as percentage 

of nominal heat output

--

69.5

%

Radiant factor

Envelop losses

Radiant factor at 

nominal 

heat output

RF

nom

55.3

%

Envelope insulation class 

U

0.0

W/m

2

K

Radiant factor at 

minimum 

heat output

RF

min

53.4

%

Envelope loss factor

F

env

0.0

%

Regulation (EU) 2015/1188

Heat generator to be installed 

outside the heated area

Yes

No

Possible

Auxiliary electricity consumption 

Heat output control type

At Nominal heat 

output

el

max

0.10

kW

- Single stage (ON-OFF)

Yes

No

At minimum heat 

output 

el

min

0.06

kW

- Two stage (100%-60%-OFF)

Yes

No

In standby 

mode 

el

sb

0.0

kW

- Modulated

Yes

No

Permanent pilot flame power requirement

Pilot flame power 

requirement (if 

applicable)

P

pilot

0.0

kW

Contact 

details

PAKOLE Trade Kft. H-8000, Székesfehérvár. Börgöndi út. 8-10

Содержание ZENIT-12 Series

Страница 1: ...PROPANE OR NATURAL GAS FIRED ZENIT TYPE TUBE RADIANT HEATER EN www pakole com Appliance types ZENIT 12 58kW Linear and U form types For users Zenit_009_001 013_001_220609_V007_EN User s Manual...

Страница 2: ...regulators 9 Control of appliance 9 Heat radiated area 9 Protective distances 10 Combustion air supply 12 6 Air supply and venting system types 12 7 Appliance operation 13 8 Appliance specification 1...

Страница 3: ...cause serious bodily injuries or damages as fol lows burning explosion suffocation carbon monoxide poisoning electric shock and in extreme case death This appliance can only be used and serviced by su...

Страница 4: ...mals from the equipment Never service mend such devices which are hot and during operation or electrical charged Never mount such air duct unit on front or back side of device which is not approved by...

Страница 5: ...corners of outdoor units Keep suction grids always clear Before cleaning or maintaining the unit make sure that all electrical parts have been switched off the appliance gas supply chain is closed and...

Страница 6: ...owing The package must be carefully secured in the loading space The package must be transferred in a closed space always keep packing parts away environmental impacts The unit has a special safety pa...

Страница 7: ...d but it must be placed minimum 6m far from the burner U form tube radiant heater appliance see fig 3 At the U pipe appliance in case of non side wall placing execution which is not suspended at an an...

Страница 8: ...erated under dry circumstances At electrical installation of appliance the relevant standard must be considered The mains connection can be executed by grounded plug or fixed properly installed phase...

Страница 9: ...nce The appliance always starts the operation with 100 power and when the sensed temperature reaches the adjusted temperature on the thermostat then it automatically reduces the power to the pre adjus...

Страница 10: ...8 m 0 8 m 16 20 kW 0 12 m 1 3 m 0 6 m 0 9 m 0 8 m 22 28 kW 0 15 m 1 5 m 0 8 m 1 0 m 1 0 m 30 36 kW 0 15 m 1 6 m 0 8 m 1 0 m 1 0 m 38 44 kW 0 18 m 1 6 m 1 0 m 1 0 m 1 0 m 46 52 kW 0 18 m 1 8 m 1 0 m 1...

Страница 11: ...ave to be executed by hanger located on the fan side of burner and combination brackets 30 picture Suspension possibilities When placing the suspensions the correct suspension of the burner must also...

Страница 12: ...d 15 m in length Maximum two 90 elbows may be used Combustion air supply Exhaust arrangements of combustion products Flue channel to the outside of building at each appliance Common flue channel for t...

Страница 13: ...pe is stabilized and stable electrical signal is come back from the electrode the appliance operates and the green control lamp is lighting During operation of appliance its automatic burner control c...

Страница 14: ...the appliance operates and the green control lamp is lighting During operation of appliance its automatic burner control con trols the condition of differential pressure switch and signals coming from...

Страница 15: ...ng and resetting the power supply It is advisable to make a maintenance contract for the proper maintenance or call our qualified service department for regular mainte nance ATTENTION Before any maint...

Страница 16: ...isassembling the burner Disregard of this instruction can result death injury or property damage Gas change ATTENTION If an intervention needs the disassembling of burner turn to a qualified service d...

Страница 17: ...anging 11 Enclosure Enclosure 1 Variety list of ZENIT type tube radiant heaters length weight Radiant tube type Appliance length m L6 U3 L9 U4 5 L12 U6 L15 U7 5 L18 U9 L21 U10 5 6 65 3 86 9 57 5 29 12...

Страница 18: ...8 2 08 1 65 1 6 ZENIT 22 22 7 2 38 1 9 1 83 ZENIT 24 24 4 2 56 2 04 1 97 ZENIT 26 26 2 2 75 2 19 2 12 ZENIT 28 28 2 2 96 2 36 2 28 ZENIT 30 30 6 3 21 2 56 2 47 ZENIT 32 31 9 3 35 2 67 2 58 ZENIT 34 34...

Страница 19: ...32 ZENIT 30 30 6 17 1 3 21 1 8 2 56 1 43 2 47 1 38 ZENIT 32 31 9 20 1 3 35 2 11 2 67 1 68 2 58 1 62 ZENIT 34 34 6 21 1 3 63 2 22 2 89 1 76 2 8 1 71 ZENIT 36 36 5 22 7 3 83 2 38 3 05 1 9 2 95 1 83 ZEN...

Страница 20: ...h min 81 19 Minimum heat output as percentage of nominal heat output 63 8 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 50 7 Envelope insulation class U 0 0 W m2K Radiant f...

Страница 21: ...th min 81 39 Minimum heat output as percentage of nominal heat output 61 3 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 51 2 Envelope insulation class U 0 0 W m2K Radiant...

Страница 22: ...th min 81 57 Minimum heat output as percentage of nominal heat output 62 3 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 52 7 Envelope insulation class U 0 0 W m2K Radiant...

Страница 23: ...th min 81 84 Minimum heat output as percentage of nominal heat output 62 5 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 54 6 Envelope insulation class U 0 0 W m2K Radiant...

Страница 24: ...th min 81 60 Minimum heat output as percentage of nominal heat output 69 5 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 55 3 Envelope insulation class U 0 0 W m2K Radiant...

Страница 25: ...th min 82 08 Minimum heat output as percentage of nominal heat output 65 4 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 56 5 Envelope insulation class U 0 0 W m2K Radiant...

Страница 26: ...th min 80 85 Minimum heat output as percentage of nominal heat output 63 8 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 52 4 Envelope insulation class U 0 0 W m2K Radiant...

Страница 27: ...hth min 81 10 Minimum heat output as percentage of nominal heat output 61 3 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 53 3 Envelope insulation class U 0 0 W m2K Radiant...

Страница 28: ...th min 81 30 Minimum heat output as percentage of nominal heat output 62 3 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 54 4 Envelope insulation class U 0 0 W m2K Radiant...

Страница 29: ...hth min 81 50 Minimum heat output as percentage of nominal heat output 62 5 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 55 9 Envelope insulation class U 0 0 W m2K Radiant...

Страница 30: ...th min 81 40 Minimum heat output as percentage of nominal heat output 69 5 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 56 7 Envelope insulation class U 0 0 W m2K Radiant...

Страница 31: ...hth min 80 97 Minimum heat output as percentage of nominal heat output 65 4 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 57 6 Envelope insulation class U 0 0 W m2K Radiant...

Страница 32: ...able part and mending which is done by not authorized retailer or service station The regular maintenance is the owner s responsibility The manufacturer does not assume the responsibility in case of a...

Страница 33: ...ZENIT TYPE TUBE RADIANT HEATER User s Manual 33...

Страница 34: ...ZENIT TYPE TUBE RADIANT HEATER User s Manual 34...

Страница 35: ...ZENIT TYPE TUBE RADIANT HEATER User s Manual 35...

Страница 36: ...PAKOLE TRADE Ipari s Kereskedelmi Kft H 8000 Sz kesfeh rv r B rg ndi t 8 10 www pakole com mail pakole hu Tel 36 22 316 484 www pakole com...

Отзывы: