ZENIT
TYPE TUBE RADIANT HEATER
User’s Manual
11
Maximal angle at a complete appliance: (max.30°)
Suspension
After determining the number and exact position of appliances and hangers,you have to provide for hanging them at a minimum of
400 mm (hanging chains for example)� This is necessary, so it does not hinder the length change, which increases dueing thermal
expansion,hereby appliances does not deform� Install hangers under the roof structure, under buttresses or scaffolding among columns
or nerby wall�The suspension of appliances have to be executed by hanger located on the fan side of burner and combination brackets�
30. picture: Suspension possibilities
When placing the suspensions, the correct suspension of the burner must also be taken into account, be-
cause due to the incorrect suspension, during the thermal expansion, deformations can occur on the burner tube�
Do not suspend the burner vertically, but pull it slightly towards the burner using the chain�
It is recommended to use a chain tensioner for perfect suspension�
Example for location of suspensions
27 picture: Maximal angle of installation
ATTENTION! The appliance must be installed in such a way that its rise is at least 0.5% and maximum
1% from the burner to the exhaust outlet.
min. 400 mm
min. 400 mm