ZENIT
TYPE TUBE RADIANT HEATER
User’s Manual
10
From flammable materials it is obligatory to keep
SAFETY OF OPERATION
and
FIRE PREVENTION
distances!
ATTENTION! The specified fire-protection distances – Pic.26 – must be strictly kept and checked!
The installation must comply with the valid standards!
Disregard of these instructions can result in death, injury or property damage!
Protective distances
The minimal mounting height
26.picture: Fire-protection distances
C
1
E
Power
Protective distances
A
B
C
C1
E
12–14 kW
0�12 m
1�1 m
0�3 m
0�8 m
0�8 m
16–20 kW
0�12 m
1�3 m
0�6 m
0�9 m
0�8 m
22–28 kW
0�15 m
1�5 m
0�8 m
1�0 m
1�0 m
30–36 kW
0�15 m
1�6 m
0�8 m
1�0 m
1�0 m
38–44 kW
0�18 m
1�6 m
1�0 m
1�0 m
1�0 m
46–52 kW
0�18 m
1�8 m
1�0 m
1�2 m
1�2 m
54–58 kW
0�18 m
2�0 m
1�2 m
1�5 m
1�2 m
ZENIT
Pipe
position
Minimum installation height for input power
10 kW 15 kW 20 kW 25 kW 30 kW 35 kW 40 kW 45 kW 50 kW 55 kW 60 kW
„U”
form
Horizontal
3�4 m
3�7 m
4�0 m
4�2 m
4�4 m
4�6 m
4�9 m
5�2 m
5�4 m
5�7 m
5�9 m
30°
3�0
m
3�2
m
3�4
m
3�7
m
3�9
m
4�1
m
4�3
m
4�6
m
4�8
m
5�0
m
5�3
m
„L” form Horizontal
3�2
m
3�5
m
3�7
m
4�0
m
4�2
m
4�5
m
4�7
m
5�0
m
5�2
m
5�4
m
5�6
m
30°
2�7
m
3�0
m
3�2
m
3�4
m
3�6
m
3�9
m
4�1
m
4�3
m
4�5
m
4�7
m
4�9
m
28.picture Minimal ascent of installation