26
LED
Code
Smart View
Fault Code
Fault
Category
Possible Cause
Fault Clearance
13
F43105
4
Less than 10% of the stack is free
on one of the RTOS tasks.
Internal hardware fault.
13
F43106
4
An internal logic supply rail has
gone out of range.
14
F44101
4
EMCY message received from
non-Sevcon node and anonymous
EMCY level was set to 4.
CVheck status of non-
Sevcon nodes on CANbus.
1
F51001
5
Detected controller hardware ver-
sion incompatible with software.
Check correct software is
programmed into control-
ler. Reprogram if necessary.
1
F51002
5
Calibration settings in controller
are out of range.
Controller requires recali-
bration in production.
3
F53001
5
Voltage on B+ terminal exceeds
rated maximum for controller.
Check battery condition
and wiring.
3
F53002
5
Motor current exceeded control-
ler-rated maximum.
Check motor configuration
and wiring.
3
F53003
5
MOSFET/IGBT s/c detection on M1
top devices.
Check motor wiring. Check
controller condition.
3
F53004
5
MOSFET/IGBT s/c detection on M1
bottom devices.
Check motor wiring. Check
controller condition.
3
F53005
5
MOSFET/IGBT s/c detection on M2
top devices.
Check motor wiring. Check
controller condition.
3
F53006
5
MOSFET/IGBT s/c detection on M2
bottom devices.
Check motor wiring. Check
controller condition.
3
F53007
5
MOSFET/IGBT s/c detection on M3
top devices.
Check motor wiring. Check
controller condition.
3
F53008
5
MOSFET/IGBT s/c detection on M3
bottom devices..
Check motor wiring. Check
controller condition.
3
F53009
5
Unable to complete MOSFET/IGBT
tests at power up.
Internal software fault.
3
F53010
5
IGBT driver failure
Check status of IGBT
3
F53011
5
IGBT driver failure
Check status of IGBT
3
F53012
5
IGBT driver failure
Check status of IGBT
3
F53013
5
IGBT driver failure
Check status of IGBT
3
F53014
5
IGBT driver failure
Check status of IGBT
3
F53015
5
IGBT driver failure
Check status of IGBT
13
F53101
5
Unable to identify hardware
Internal hardware fault
14
F54101
5
EMCY message received from
non-Sevcon node and anonymous
EMCY level is set to 5.
Check status of non-
Sevcon nodes on CANbus.
Fault Codes and Troubleshooting Chart (continued)
Содержание PC NXG Series
Страница 1: ...INDUSTRIAL ELECTRIC VEHICLE PC NXG and PCT NXG Series April 2017 ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 46: ...40 Appendix H Transaxle PC Series ...
Страница 48: ...Appendix I Transaxle PCT Series Series ...